WARNING Risk of Electrical Shock and Fire.
The heater must be properly installed before it is
used.
1. Do not operate without grill.
2. Keep electrical cords, drapery, furnishings and
other combustibles at least 3 feet away from the
front of the heater and 6 inches away from the
sides.
3. Do not tamper with the over temperature limit
control.
4. If the heater over temperature limits trip more
than once per day, the heater must be replaced.
How to operate your heater
The room temperature is controlled by a line voltage thermostat
located either on the wall or built-in to the heater.
1. Once installation is complete and power has been restored,
turn the thermostat knob fully clockwise.
2. When the room reaches your comfort level, turn the thermo-
stat knob counterclockwise until the heater turns off. The heater
will automatically cycle around this preset temperature.
3. To reduce the room temperature, turn the knob counterclock-
wise. To increase the room temperature, turn the knob clockwise.
Resetting the Manual Reset Temperature Limit Control
If the manual reset limit control has opened the heater circuit due to excessive operating
temperatures, the heater will not work until the manual reset limit button is pressed.
After allowing the unit to cool for at least 10 minutes and resolving the problem causing the limit
to trip (typically the heater is blocked or needs cleaning-see Maintenance Instructions); use a
narrow object such as a ball-point pen to access the manual reset button through the upper-
left center section of the heater grill. Press FIRMLY and be sure to listen and feel for a click,
indicating it has been reset.
For more effective and safer operation and to prolong the life of
the heater, read the Owner's Guide and follow the maintenance
instructions. Failure to properly maintain the heater will void any
warranty and may cause the heater to function improperly. War-
ranties are non transferable and apply to original consumer only.
Warranty terms are set out below.
LIMITED THREE-YEAR WARRANTY: Cadet will repair or re-
place any Com-Pak Max (CM) heater found to be defective within
three years after the date of purchase.
These warranties do not apply:
1. Damage occurs to the product through improper installation or
incorrect supply voltage;
2. Damage occurs to the product through improper maintenance,
misuse, abuse, accident, or alteration;
3. The product is serviced by anyone other than Cadet;
4. If the date of manufacture of the product cannot be deter-
mined;
5. If the product is damaged during shipping through no fault of
Cadet.
6. CADET'S WARRANTY IS LIMITED TO REPAIR OR RE-
PLACEMENT AS SET OUT HEREIN. CADET SHALL NOT BE
LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR
FOR CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EX-
PENSES RESULTING FROM BREACH OF THESE WRITTEN
WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY.
OPERATING INSTRUCTIONS
Resetting the Manual Reset Limit Control
Warranty
5. Clean heater at least every six months.
6. After allowing the heater to cool, turn power off
at circuit breaker panel before removing grill.
7. Use a hair dryer or vacuum on blow cycle to
blow debris through the top element (do not touch
element).
8. Install the grill before turning on power.
WARNING: Any other service not detailed in
this Owner's Guide should be performed by an
authorized service representative.
About the Manual Reset Temperature Limit Control
The heater is protected by a temperature-limiting control. The
manual reset temperature limit control is designed to open the
heater circuit when excessive operating temperatures are detect-
ed. The problem must be assessed and the limit must be reset to
resume operation.
7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART
OF YOUR CADET PRODUCT, THE REPLACEMENT PARTS
ARE SUBJECT TO THE SAME WARRANTIES AS THE PROD-
UCT. THE INSTALLATION OF REPLACEMENT PARTS DOES
NOT MODIFY OR EXTEND THE UNDERLYING WARRANTIES.
REPLACEMENT OR REPAIR OF ANY CADET PRODUCT OR
PART DOES NOT CREATE ANY NEW WARRANTIES.
8. These warranties give you specific legal rights, and you may
also have other rights which vary from state to state. Cadet nei-
ther assumes, nor authorizes anyone to assume for it, any other
obligation or liability in connection with its products other than as
set out herein.
If you believe your Cadet product is defective, please contact
Cadet Manufacturing Co. at 360-693-2505, during the warranty
period, for instructions on how to have the repair or replacement
processed. Warranty claims made after the warranty period has
expired will be denied. Products returned without authorization
will be refused.
Parts and Service
Visit cadetheat.com/parts-service for information on where to
obtain parts and service.
Reduce-Reuse-Recycle
This product is made primarily of recyclable materials. You can reduce
your carbon footprint by recycling this product at the end of its useful
life. Contact your local recycling support center for further recycling
instructions.
Manual
Reset
Limit
Button
Page 5