Internal sensor parameters
Parameter
Index
Name
Hex(Dec)
Process Data
Configuration
Switching
Output (SO)
Binary Data
Channel 1
(BDC2)
0x46(70)
Binary Data
Channel 2
(BDC1)
Temperature
Alarm (TA)
Temperature Alarm
Threshold
High Threshold
0x48(72)
Low Threshold
Event
Configuration
Temperature
fault event
Temperature
0x4A(74)
over-run
Temperature
under-run
LED Activation
0x4E(78)
Max temperature
0xCD(205)
since start-up
Min temperature
0xCE(206)
since start-up
Current
0xCF(207)
temperature
Switching
0xD0(208)
frequency
Detection counter
0xD2(210)
Subindex
Access
Hex(Dec)
0x02(2)
R/W
0x04(4)
R/W
0x05(5)
R/W
0x08(8)
R/W
0x01(1)
R/W
0x02(2)
R/W
0x02(2)
R/W
0x03(3)
R/W
0x04(4)
R/W
0x00(0)
R/W
0x00(0)
R
0x00(0)
R
0x00(0)
R
0x00(0)
R
0x00(0)
R
Rev. 00 | IBS04, ICS05, ICS08, ICB12, ICB18, ICB30 Sensores inductivos con interfaz IO-Link | © 2018 | CARLO GAVAZZI Automation
Default value
0 = SO not shown in PDV
1
0 = BDC1 not shown in PDV
0
1 = BDC1 shown in PDV
0 = BDC2 not shown in PDV
0
1 = BDC2 shown in PDV
0 = TA not shown in PDV
0
100
-30 for cable variants
-45 for plug variants
0 = Fault event disabled
0
0 = Warning event disabled
0
1 = Warning event enabled
0 = Warning event disabled
0
1 = Warning event enabled
0 = LED indication disabled
1
1 = LED indication enabled
-
-
-
-
-
Data Type
Data range
(Length)
1 = SO shown in PDV
RecordT16
1 = TA shown in PDV
-32768 to 32767 °C
IntegerT16
-32768 to 32767 °C
IntegerT16
1 = Fault event enabled
RecordT16
UIntegerT8
-32768 to 32767 °C
IntegerT16
-32768 to 32767 °C
IntegerT16
-32768 to 32767 °C
IntegerT16
0 to 32767 Hz
IntegerT16
0 to 2147483647
IntegerT32
25