Programming
Test Cycle
(Continued)
l. The cold water fill valve turns off. The
recirculation pump output is energized for
ten seconds, provided that the water level
switch indicates that at least low water level
is present. The display shows "PUnP"
(recirculation pump output on).
m. The motor rotates clockwise (in reverse) at
reduced wash speed for 60 seconds. The
display alternately flashes "SLo" and "rEv"
(normal wash speed, clockwise).
n. The motor rotates counterclockwise
(forward) at reduced wash speed for 60
seconds. The display alternately flashes
"SLo" and "For" (reduced wash speed,
counterclockwise).
o. The motor rotates clockwise (in reverse) at
normal wash speed for 60 seconds. The
display alternately flashes "norM" and "rEv"
(normal wash speed, clockwise).
p. The motor rotates counterclockwise
(forward) at normal wash speed for 60
seconds. The display alternately flashes
"norM" and "For" (reduced wash speed,
counterclockwise).
q. The display begins alternately flashing
"drAI" and "For" (drain step, cylinder
rotating at wash speed). The motor continues
to rotate counterclockwise (forward) at
normal wash speed for seven seconds.
r. The motor accelerates to distribution speed.
The display alternately flashes "drAI" and
"dISt" (drain step, cylinder rotating at
distribution speed).
30
s. The drain opens 15 seconds into the drain
step. The water level indicator lights on the
display will begin to go out, one by one, as
the machine drains past each water level.
t. The computer begins monitoring the balance
signal from the AC inverter drive eight
seconds after the water level switch indicates
that water level has dropped below low level.
u. If the balance signal indicates that the wash
load is unbalanced, the cylinder will slow
down to wash speed for seven seconds in an
attempt to redistribute the load. The
computer will make as many as ten attempts,
as needed, in this cycle.
Note:
If the machine utilizes the overtravel limit
switch balance detection system, the computer will
proceed through the drain step and will time steps t
and u. The computer will then proceed to step v.
v. The cylinder accelerates to low spin speed.
The display shows "SPn1" (cylinder rotating
at low spin speed). The basket rotates at low
spin speed for 60 seconds.
w. The cylinder accelerates to medium spin
speed. The display shows "SPn2" (cylinder
rotating at medium spin speed). The basket
rotates at medium spin speed for 60 seconds.
x. The cylinder accelerates to high spin speed.
The display shows "SPn3" (cylinder rotating
at high spin speed). The basket rotates at
high spin speed for 60 seconds.
F232072