Programming
Cycle Segment Charts
Display
PrE
00 or 02 to 30
tFIL
HFIL, CFIL, bFIL,
or AFIL
LO, Med, or HI
SUP0–SUP7
00°F, 75°F–200°F
00°C, 25°C–93°C
drAI or nodr
SPIn (flashed for one second)
tIME (flashed for one second)
00 or 30 to 240
* This is displayed only if temperature-controlled fills are enabled in the SETUP options and if the heat
temperature is set to a value other than "00."
** "AFIL" can be selected only if the "SUP5"/"AFIL" SETUP option is set to "AFIL."
*** "SUP5" and "SUP6" can be selected only if the "SUP5"/"AFIL" SETUP option is set to "SUP5."
† This value is not available when temperature-controlled fill and auxiliary heat SETUP options are
disabled.
‡ If "nodr" is selected, the computer skips the spin step and goes on to the next segment.
32
Segment 1 (Prewash)
Use Up or Down key to change. Press Start key to enter or advance.
Select segment time: 02 to 30 minutes (00 to skip segment).
Indicates temperature fill is enabled.*
Select "HFIL" (hot fill), "CFIL" (cold fill), "bFIL" (warm fill), or "AFIL"
(auxiliary fill).**
Select fill level: "LO" (low), "Med" (medium), or "HI" (high) water level.
Select supply 0 – 7 (0 for no supply).***
Select temperature: 75 to 200° F or 25 to 93° C (00 for no heat).†
Select drain option: "drAI" (drain), "nodr" (no drain)‡
Select time for spin: 30 to 240 seconds (00 for no spin)
Instructions
F232072