Specifications; Standard Equipment; Machine Assembly - RIDGID K-750R Manual

Limpiadora de desagües
Ocultar thumbs Ver también para K-750R:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

set value. This helps to prevent cable damage from cable
flip over in the drum. The torque limiter is designed to work
with RIDGID C-24 HD
5
/
" x 100' cable, and may not pro-
8
tect other cables.
Handle
Warning
Label
Drum
Manual Feed
Assembly
GFCI and
Line cord
Frame
Foot Switch
Figure 1 – K-750R Drain Cleaning Machine
Figure 2 – Machine Serial Number
The machine serial number is located on the back of
the power unit. The last 4 digits indicates the month and
year of the manufacture. (06 = month, 19 = year).

Specifications

Line Capacity.................3 – 6 (75 mm to 150 mm)
Lines, Up To 100 feet (30.5 m)
Drum Capacity...............100' of
16 mm)
Cable Type ....................RIDGID Cat. # 37754 C-24
HD
278-109-441.10_REV. B
Loading Wheel
FOR/O-OFF/REV
Switch
Belt Guard
Cable
Serial Plate
(Back)
Stair
Climber
Wheel
Kickstand
5
/
" Cable (30.5 m of
8
5
/
" x 100'
8
K-750R Drain Cleaning Machine
Motor Type ....................Induction
Motor Rating..................120 VAC, Single Phase,
6.5 A, 60Hz
No Load Speed .............200 r/min (RPM)
Controls .........................FOR/O-OFF/REV Switch,
Pneumatic Foot Switch
Operating
Temperature..................-20° F to 120° F
(-29° C to 49° C)
Storage Temperature ....-20° F to 140° F
(-29° C to 60° C)
Weight (Machine Only) ...95 lbs. (44 kg)
With 100'
5
/
" C-24 HD Cable.........180 lbs. (82 kg)
8
Dimensions:
Length .........................26" (660 mm)
Width ...........................21" (533 mm)
Height ..........................43" (1092 mm)
Sound Pressure (L
)* .......58 dB(A), K=3
PA
Sound Power (L
)*...........59.3 dB(A), K=3
WA
* Sound measurements are measured in accordance with a standardized test per
Standard EN 62481-1.
- Sound emissions may vary due to your location and specific use of these
tools.
- Daily exposure levels for sound need to be evaluated for each application and
appropriate safety measures taken when needed. Evaluation of exposure lev-
els should consider the time a tool is switched off and not in use. This may
significantly reduce the exposure level over the total working period.

Standard Equipment

All K-750R Drain Cleaning Machines come with one
pair of RIDGID Drain Cleaning Gloves. Refer to the
RIDGID catalog for details on equipment supplied with
specific drain cleaner catalog numbers.
NOTI E
This machine is made to clean drains. If prop-
erly used it will not damage a drain that is in good condi-
tion and properly designed, constructed and maintained.
If the drain is in poor condition, or has not been properly
designed, constructed and maintained, the drain cleaning
process may not be effective or could cause damage to
the drain. The best way to determine the condition of a
drain before cleaning is through visual inspection with a
camera. Improper use of this drain cleaning machine
can damage the drain cleaning machine and the drain.
This machine may not clear all blockages.

Machine Assembly

WARNING
To reduce the risk of serious injury during use, follow
these procedures for proper assembly.
FOR/O-OFF/REV switch should be O-OFF and ma-
chine unplugged before assembly.
5