6.2 BATTERY INSTALLATION

The battery compartment is located in the solution
tank (Photo 13 - Photo 14) and to access it is ne-
cessary to lift the closing hood of the tank (Photo
12 - A);
to lift the hood, open the closing brackets placed
on the two sides of the machine (Photo 12 - B)
(Photo 12 - C);
lift the hood and rotate it upward until you reach
the position shown in Photo 13.
Insert the batteries into the battery compartment
place (Photo 14) by carefully checking that they
are in perfect condition.

6.2.1 BATTERY CONNECTION

Place the general ON/OFF switch (Photo 5 - B)
(Photo 7 - E) in the OFF position as well as motors
switches on the control panel.
(
) Attach the wiring to the batteries, con-
necting the terminals exactly and only to the
poles marked with the same symbol (red
wiring "+", black wiring "-") according to
the wiring diagram shown in photo 15
!
(
) A short circuit of batteries can cause ex-
plosions!
Photo 14 shows the correct battery connection.
!
(
) Close the battery compartment by lifting and
rotating downward the closing hood of the recovery
tank;
block the hood by closing the brackets (Photo 12
- B).
A
Photo 14
A) Battery compartment with two 12V batteries
B) Battery connection