Battery Charger Configuration - Kruger KFL450E Manual Del Usaurio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.3 BATTERY CHARGER CONFIGURATION

!
(
) We recommend to call the assistance centre or
a technician if you have problems with the setting
given.
The machine is equipped with a battery charger
configurated for OPTIMA maintenance free
battery.
If the operator whish to use Pb-Acid battery or
GEL/AGM battery, it is necessary to change the
battery charger settings as follows:
!
(
) DISPLAY OF THE BATTERY CHARGER SET-
TINGS
The battery charger settings are shown by the
blinking of the LED indicator when the battery
charger is switching on:
- the RED LED indicator ( Photo 16 -B )
flashes 2 times = the battery charger is set for
PB-Acid batteries
- the GREEN LED indicator ( Photo 16 - C )
B
A
Photo 16
Table A
Battery
Dip-Switch 1 Dip-Switch 2
type
Optima
ON
Pb-Acido
ON
Gel / AGM
OFF
6 - INSTALLATION INFORMATIONS
E
F
SW1
ON
OFF
ON
flashes 2 times = the battery charger is set for
GEL/AGM or OPTIMA batteries
The battery charger settings will be displayed even
if the battery is not connected.
!
(
) DIP-SWITCH CONFIGURATION FOR CHARG-
ING CURVE SETTINGS FOR BATTERY CHARGER
CBHD1 24V 10A
To set the charging curve type for Pb-Acid,
GEL/AGM or OPTIMA batteries it is necessary to
operate on the dip-switches placed inside the
battery charger ( Photo 16 - D ) ( Photo 16 -
F ).
To access the dip-switches it is necessary to remove
the lower panel of the battery charger ( Photo 16 -
A ); it is also possible to reach the dip-switches by
removing the plastic cap ( Photo 16 - E ).
To configurate the charging curve related to the dif-
ferent battery type it is necessary to set the dip-
switches as indicated in the Table A here below:
A) Battery charger cover
B) Red "LED" - Battery discharged
C
C) Green "LED" - Battery charged
D) Dip-Switches
E) Plastic cap
F) Dip-Switches for charging curve set-
ting
SW1
38
SW 1
ON
ON
OFF
OFF
OFF
DIP 1
DIP 2

Publicidad

Tabla de contenido
loading

Tabla de contenido