Fitting an indoor station

You can install the inner station on the suspension eyes (12) by
means of two screws in the desired position.
Attach the connection plug (10) of the mains adapter into the
mains adapter socket (11). The voltage supply cable (14) must
be laid in the cable entry (13) on the rear side of the inner
station. Pay attention to the proximity to the next socket for the
mains adapter (3).
Connect the connection cable according to the specified colours
or numbers on the terminals (5) (see Figure B). Attach the plug
of the mains adapter (3) into the (230V~) mains socket.
Connecting up a door opener, if fitted (Illus. B)
If an electric door opener is used, of specification 12V dc /1A
(Technical Data), the entrance door can be opened using the
door open button (9) on the indoor station, connected by a 2-
core cable which must be laid from the door intercom to the door
opener.

Handling

When a visitor presses the Bell push-button (7) the ring tone is
heard on the indoor station. Now you can pick up the receiver to
speak to your visitor. If a door opener is connected, this can be
opened by pressing the door open (9) button. This is also
possible if the receiver has not been picked up. You can set the
ringtone volume with the slide switch (8) fitted on the side.