Troubleshooting
No audio connection
Door opener not working
Care
!
Always disconnect mains-operated devices before cleaning
(pull out the plug).
!
Clean the device with a damp cloth, without cleaning agents.
!
Only remove dust deposits from the ventilation slots with a
brush or a vacuum cleaner, if necessary.Only remove dust
deposits from the ventilation slots with a brush or a vacuum
cleaner, if necessary.
Technical data
Mains transformer
Line length
Power consumption:
- Stand-by
- In operation
Operating temperature
Ringtone volume
Push button for door opener
We reserve the right to make alterations without prior
consultation. As part of our product care and ongoing
improvement to our units, the contents may differ from the pack
details.
Operation of the units may be adversely affected as a result of
the effects of strong static, electric or high frequency fields
(discharges, cell phones, radio systems, mobile telephones,
microwaves).
Check that the cable is connected
correctly and is not damaged.
Does the door opener have the
specified technical data.
Is the line from the door station to the
bell push-button all right?
230V ~ , 50 Hz, 15 V / 1000 mA
max. 70m 0.75mm² (door station
- inner station)
3 Watts
10 Watts
-10°C to 50°C
80 dBA / 1 metre maximum
Contact rating: DC 12V/ max. 1A
18