Attention - Critical Points To Remember; Lighting And Shut Down - HeatStar HS125NG Instrucciones De Funcionamiento Y Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ATTENTION - CRITICAL POINTS TO
For Model HS125NG (for use with natural gas)
REMEMBER!
Piping must be clean and free from scale or burrs.
• Propane (LP) gas has a distinctive odor. Learn to
Install regulator supplied with heater. Connect with 1/2" NPT
recognize these odors. (Reference Fuel Gas Odor and
nipple (not included) to Control Valve.
Odor Fading sections above.
Connect the appliance to an appropriately designed and
• Even If you are not property trained in the service and
installed fuel supply system. This system must include an
repair of the heater, ALWAYS be consciously aware of
approved manual shut-off valve which is readily accessible and
the odors of propane (LP) gas and natural gas.
is located within six (6) feet of the appliance. Additionally, a
• If you have not been properly trained in repair and
sediment trap or drip leg must be located upstream of this
service of propane (LP) gas then do not attempt to
manual shut-off valve. Refer to the appropriate (natural gas)
installation code noted above. If a flexible connector is used,
light heater, perform service or repairs, or make any
it must be of an approved type.
adjustments to the heater on the propane (LP) gas fuel
system.
Before attempting to ignite the appliance, all gas fittings and
connections must be thoroughly checked for gas leaks. Apply a
small amount of a mild soap and water solution to all fittings and
connections and observe for escaping bubbles. If any leaks are
OPERATING INSTRUCTIONS
detected, shut off the gas supply to the appliance immediately.
Wait a minimum of five minutes, repair the leak(s) and retest for
leakage. Dry all fittings and connections after leak testing.
WARNING
WARNING
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY, A FIRE OR EXPLOSION MAY RESULT
NEVER USE A FLAME FOR GAS LEAK TESTING.
CAUSING PROPERTY DAMAGE, PERSONAL
INJURY, OR LOSS OF LIFE.
OPERATING INSTRUCTIONS
CAUTION
WARNING
THIS APPLIANCE IS HOT DURING NORMAL
OPERATION, AVOID PHYSICAL CONTACT.
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL
CAUTION
INJURY, OR LOSS OF LIFE.
DO NOT PLACE CLOTHING OR OTHER
COMBUSTIBLE MATERIALS ON THIS APPLIANCE.
CAUTION
THIS APPLIANCE IS HOT DURING NORMAL
DO NOT operate this heater if any part has been under
OPERATION, AVOID PHYSICAL CONTACT.
water. Call a qualified service technician to inspect the appliance
and to replace any part of the control system or gas control valve
which has been under water.
This appliance must be installed and operated only in locations
CAUTION
where the potential for physical damage to the appliance is
reduced to a minimum. The owner/operator of this appliance
DO NOT PLACE CLOTHING OR OTHER
must ensure that precautions are taken to protect the appliance
COMBUSTIBLE MATERIALS ON THIS APPLIANCE.
from physical damage.
DO NOT operate this heater if any part has been under
water. Call a qualified service technician to inspect the appliance
and to replace any part of the control system or gas control valve
which has been under water.
This appliance must be installed and operated only in locations
where the potential for physical damage to the appliance is
reduced to a minimum. The owner/operator of this appliance
must ensure that precautions are taken to protect the appliance
from physical damage.
Gas-Fired Infra-Red Portable Construction Heater

LIGHTING AND SHUT DOWN

Lighting the Heater
1
Before attempting to light the heater, smell all around
the heater area for gas. Be sure to smell next to the floor
because LP Gas is heavier than air and will settle on the
floor. Turn on the gas supply to the appliance and check
all fittings and connections for gas leaks using a mild
soap and water solution. NEVER use a match to check
for gas leaks. Should a gas leak occur, shut off the gas
supply to the appliance immediately. Wait a minimum of
five minutes before repairing the leak.
2
Use only the fuel intended for this appliance. Check the
appliance rating plate for the correct fuel information.
3
Depress knob then turn the gas valve knob clockwise to
the "OFF" position. See Fig. 1 and Fig. 2 for location of
appliance parts.
4
Wait a sufficient length of time (at least five minutes)
to allow gas which may have accumulated in burner
compartment to escape.
5
Turn on the main gas supply.
6a Depress and turn Control Knob counterclockwise to
"Pilot" position and hold for 1-2 minutes. This may take
longer to purge air from the supply hose depending on
the length of the hose being used.
Depress red spark ignition button to light pilot flame
(repeat until pilot lights) and continue to hold Control
Knob at "Pilot" position for 30-60 seconds to enable Pilot
Light Safety System.
Fully turn Control Knob to "ON" position to light burner.
or...
6b To light the pilot, move the lighting hole cover aside
(see Fig. 1) and place a lighted match into the hole.
Depress the gas valve knob and hold while lighting
and observing the pilot burner. Ensure that the pilot
burner ignites from the match. Allow the pilot to burn
approximately 30 seconds before releasing the gas valve
knob. If pilot does not remain lighted, repeat the lighting
operation allowing a longer period of time before
releasing the gas valve knob.
NOTE: In cases where long runs of gas supply lines have been
installed ahead of the appliance, it may be necessary to bleed
trapped air out of the supply lines before lighting the pilot.
New installations generally require bleed of supply lines. Wait
a minimum of five minutes after bleeding the supply lines
before attempting to light the heater.
Adjust pilot if necessary as noted under "Pilot Burner
Adjustment."
7.
Turn the gas valve knob counter-clockwise to the "ON"
position (see Fig. 1). The burner will light. Turn knob
clockwise until stop for low fire position.
8.
IMPORTANT: DO NOT attempt to adjust the main
burner input beyond stop, for this may cause the pilot
and thermocouple to shut down the burner (Fig. 2).
5
Operating Instructions and Owner's Manual

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Hs125lp