Wall Installation
Mounting Slots
Electrical Connections
WARNING
ELECTRIC SHOCk HAzARD:
• Units supplied without an electrical plug require field
installation of proper plug. Plug must be properly
grounded
and
of
configuration for electrical specifications of unit.
Contact a qualified electrician to determine and install
proper electrical plug.
• Units supplied without an electrical cord and plug
require field installation of proper cord and plug or a
hardwired connection to on-site electrical system.
Connection must be properly grounded and of correct
voltage,
size,
and
specifications of unit. Contact a qualified electrician to
determine and install proper electrical connection.
• When installing a hardwired unit, a 2-pole or 3-pole
switch (depending on unit) must be installed between
unit and main electrical supply. The switch must be
rated properly and have contacts with a minimum
opening distance of 3 mm (1/8").
• Unit must be connected to an equipotential system that
complies with the latest electrical standards.
correct
voltage,
size,
configuration
for
electrical
Make sure electrical supply matches the voltage and
frequency rating on the specification label. Incorrect
electrical supply may damage the unit.
Hardwired Connection
and
Cord and Plug Connection
NOTE: The specification label is located on the side of the unit
near the power inlet. See the label for verification of unit
electrical information.
NOTE: The plug and receptacle must be grounded in
accordance with current standards.
INSTALLATION
NOTICE
Power Inlet
Access Panel