General Characteristics - Astralpool Net'N'Clean Nozzle Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
ENGLISH
IMPORTANT: The instruction manual you are holding includes essential information on the safety measures to be
implemented for installation and start-up. Therefore, the installer as well as the user must read the instructions
before beginning installation and start-up.
Keep this manual for future reference.
To achieve optimum performance of the NET 'N' CLEAN NOZZLES, follow the instructions provided below:
1. VERIFY THE CONTENTS:
The following items are included inside the box:
• 12 inner jet casings.
• 1 spanner.
• 1 installation and maintenance manual.

2. GENERAL CHARACTERISTICS:

The nozzles turn on each other, turning 30º on each pulse.
See the table for configuration details and graphs showing the load loss and range (Fig. 5-6).
3. INSTALLATION:
Before putting the inner jet casings in place, run the system to clean any dirt that may have remained in the
piping.
Place the inner jet casings inside the outer casing by turning anti-clockwise "CLOSE" with the help of the
spanner included in the packaging. (Fig. 4).
If one of the jets spays water outside of the pool when switched on, it is recommended that the surface of the
outflow nozzle be changed (see next step).
4. CHANGING THE OUTPUT SURFACE:
• Remove the inner unit if it is located in the housing body by turning the valve to clockwise to "OPEN" (Fig. 4).
• Use a sharp object to tighten the safety pin located on the upper part of the moveable body while turning the
outlet plug to the left to "OPEN" and pull upwards (Fig. 3).
• Point the outlet plug slightly to the left of the desired position until it makes contact with the inlet of the
bayonet socket. Tighten the safety pin and turn to the right to "CLOSE" until you can hear the sound of the
safety pin.
• Reassemble the inner unit in the housing body by turning to the left to "CLOSE" (Fig. 4).
Note: The inner jet casings are supplied by the manufactured with an S4 outflow nozzle.
5. POSSIBLE BREAKDOWNS:
If the nozzle is nor raised or lowered due to dirtiness, remove the inner unit of the nozzle (following the pro-
cedure shown in Fig. 4 in the opposite order) and the outlet plug (Fig. 3). Clean the inner part of the guide
body thoroughly.
6. SAFETY WARNINGS:
• It is recommendable to start up the NET'N'CLEAN system when there are NO BATHERS IN THE SWIMMING POOL.
• Nozzles should be installed by qualified fitters.
• It is not recommended the use of sealing putty in this product and, in any case, use only products specifically
conceived to work with PVC, remaining all those products of universal use excluded.