IMPORTANT: Do not overload the generator. Also, do
not overload individual panel receptacles. These outlets
are protected against overload with push-to-reset or tog-
gle type circuit breakers. If amperage rating of any circuit
breaker is exceeded, that breaker opens and electrical
output to that receptacle is lost. Read "Generator Loads"
carefully.
3.6 — S
T
TOPPING
+
NEVER start or stop the engine with electrical
devices plugged in and turned on.
1. Shut off all loads, then unplug the electrical loads
from the generator's panel receptacles or extension
cord.
2. Let the engine run at no-load for several minutes to
stabilize the internal temperatures of the engine and
generator.
3. See Figure 3-4. Rotate the PowerDial clockwise to
the STOP position. This will shut down the engine
and turn off the fuel flow by closing the fuel valve.
Figure 3-4. PowerDial STOP position
3.7 — R
ESTARTING THE
If the generator has cooled completely, use the starting procedures
outlined in 3.4 or 3.5. However, if the generator is at or near operating
temperature, use the following steps when restarting the unit.
+
.Never start or stop engine with electrical devices
plugged into the receptacles AND devices turned on.
16
G
HE
ENERATOR
NOTE
G
ENERATOR
The generator is shut off and the PowerDial is turned to the
STOP position. Turning the PowerDial counterclockwise, past
the RUN position, turns on the fuel again and permits use of the
electric starter. The PowerDial MUST be turned from the STOP
position to just past the RUN position to restart the fuel flow.
Do not turn far. The choke is not required if the engine is hot.
Figure 3-5. PowerDial in the hot restart position
1. See Figure 3-5. To restart a hot generator, turn the
PowerDial counterclockwise, from the STOP posi-
tion, until it is just past the RUN position. This will
reopen the fuel valve and permit electric start or
recoil starting.
2. Press the PowerDial button in this position to electric
start. (7.0 kW only) or firmly grasp the recoil handle
and pull slowly until increased resistance is felt. Pull
rapidly up and away to pull start engine.
3. Then turn the PowerDial clockwise to the RUN posi-
tion.
3.8 — L
O
L
OW
IL
EVEL
S
YSTEM
The engine is equipped with a low oil level sensor that
shuts down the engine automatically when the oil level
drops below a specified level. If the engine shuts down by
itself and the fuel tank has sufficient fuel, check engine oil
level.
RS5500 / RS7000E PowerDial Series Portable Generators
NOTE
S
HUTDOWN