IMPORTANT INFORMATION

The strength of the Complice Security Safes has been tested by the
national test laboratory CNPP (burglary tests), IBMB (fire tests).
It is manufactured in accordance with the standards for certified safes.
The plant A2P security label is proof thereof.
ANY MODIFICATION SUBSEQUENT TO MANUFACTURE, SUCH AS:
- the replacement of the principal lock with a lock that does not strictly
meet the same references,
- any modification, of whatever type or extent, to the locks,
OR ANY EXTERNAL EVENT AFFECTING IT, SUCH AS :
- fire,
- attempted entry, forcing, ...
will lead to the immediate suspension of the approval of the safe
and its characteristics with regard to its insurance guarantees.

INSTALLATION OF FREE STANDING SAFE

PRINCIPLE
The specific A2P regulation H71 concerning equipment certification isued
by CNPP cert (avril 1999 editions. States: All safes weighting less than
1000 kg must be secured or built in.
MEANS
All COMPLICE safes are equipped with slots on their lower and back
surfaces allowing them to be mounted with the aid of a mounting kit
comprising:- 1 M12 peg.
RECOMMENDATIONS
We would like to draw your attention to the fact that a support of solid
oncrete, resistant to compression and of a minimum thickness of 150
mm, is required for proper mounting.
Moreover, if the safe is stood against a wall, it is important to minimise
the play between the wall and the safe.
TECHNIQUE
Bore a 18-mm diameter hole through the support.
Set in the peg to a depth of 100 mm.
Tighten to a couple between 70 and 90 N.m.