Operating Instructions
1
2
a.) Installation
The fastening hole (5) is used for wall mounting. The appliance must be mounted against a perpendicular, fireproof wall
with the power cable at the bottom, see above figure. For outside installation the device must also be protected against
exposure to rain and direct sunlight.
b.) Functional description of the appliance
Put the appliance into service without fence and earth. If the indicator light (1) flashes at the pulse rate, the appliance is
ready for use.
If the indicator light (1) does not flash, check the supply voltage and/or the power cable. If no fault is found, the appliance
should be checked by a technician.
c.) Functional description with connected fence system ( fence + earth )
1. Connect fence system and earth
2.
Insert 230V power cable
Indicator
Function
light (1)
flashes
Fence and
3.
green
earth OK
Fault:
insufficent earth
flashes
4.
red
Fault:
Fence system
shorted to earth
does not
5.
Appliance NOK
flash
If the indicator light flashes faster than approx. once per second, the appliance must be disconnected at once and
checked by a technician before it can be used again.
New function in accordance with EN 60335-2-76 A12: 2010
Following a delay time of 15 seconds this device delivers an output energy of no more than 5 joules. With an increasing
load the device increases its output energy after a delay time has lapsed and therefore automatically adjusts the shock
strength to the increased growth, weather conditions and fence status.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
-
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, warranty terms and
conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
4
This energizer shall not be used as an animal
trainer (inside a barn)!
Connection to
Fence voltage
> 2500V
= min. requirement
< 2500 V
= insufficient
230 V
Remarks
Fence system OK!
(prerequisite: fence system not interrupted)
Fault :
Voltage on earth electrode > 1000V
see fault finding in enclosed instruction manual (Figure 2, p. 5)
Fault condition: low fence voltage, no excessive voltage on earth
electrode
Measure voltage on fence: min. value: 2500V throughout the fence
see fault finding in enclosed instruction manual (Figure 2, p. 5)
See above: b.) Functional check of the appliance
3
Indicator light
5
(flashes to indicate that the
1
appliance is ready for use)
3
2 230V ~ power cable
3 Earth connection
~!
4 Fence connection
5 Fastening hole
-EN-
Version : 2017.4