Problem
Unit won't start
Unit won't stay running
LCD
LED–Red LED Flashing
at 7 second intervals
Unit won't stay Running
LCD
LED–Flashing Red/Orange
at 7 seconds intervals
Unit shut down
LCD
LED–Flashing Red/Green
at 7 seconds intervals
Unit shut down
LCD
LED–Double Flashing Red
LED at 7 seconds intervals
Unit shut down
LED – Solid Red
Low or No Catch
Customer Care **Please have your serial number, date of purchase & model type available**
All of us at Woodstream
Corporation want you to get complete satisfaction from your trap. Should you have any problems you cannot resolve, simply call one of our
®
trained Customer Care Representatives at 1-800-953-5737 or visit www.mosquitomagnet.com.
We will help you get up and running.

Troubleshooting

Possible Cause
1. Propane tank may be empty.
2. If propane tank is new and has
been newly filled it must be purged.
3. There could be a loose connection.
4. Fuel line maybe blocked by propane
contaminants.
5. Regulator is not fully engaged.
6. Bug bag may be full or clogged.
1. Low Battery Voltage
1. High Temperature
1. Thermister Fault
1. Electrical Fault
1. Insects may not be out yet.
2. Trap placement issue.
3. Biting insect reproductive cycles
have not yet been broken.
4. Counterflow may be disrupted.
Solutions
1. Weigh tank and check against "empty" weight
2. Bring tank to filling location. Air may be in
fuel line. Ask for tank to be purged.
3. Verify all connections. Make sure propane tank valve
is fully open.
4. Replace the bug bag.
1. Charge the battery before the first use and at the
beginning of each season. The Charger LED will be
Green when the battery is fully charged.
2. Check battery connection, make sure it is fully
inserted and locked.
3. If a fully charge battery indicates Low Battery Voltage
during the cycle, recharge or replace the battery.
1. Turn off trap and allow to cool for one hour, then
restart. If the code continues call Customer Care at:
1-800-953-5737.
1. Contact Customer Care at: 1-800-953-5737.
1. Contact Customer Care at: 1-800-953-5737.
1. Verify temperature is consistently over 50°F (10°C).
2. Follow steps in the "Trap Placement" section of your
owner's manual or refer to your instructional CD-ROM
included with your trap.
3. Keep trap in constant operation 24 hours/day, 7 days
per week for at least 4 weeks to reduce the mosquito
population.
4. Air flow may be restricted. Contact your Local
Service Provider.