Work Area: Figure 5 - Sammic TRX-21 Instrucciones

Turbotrituradores
Ocultar thumbs Ver también para TRX-21:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Each machine is identified as follows:
-Name and address of the manufacturer:
SAMMIC S.L - Basarte 1 Azkoitia. Gipuzkoa
(SPAIN)
-The serial number is printed on the Guarantee
Card and in the Declaration of Conformity.
MODELS
This manual describes the installation, opera-
tion and maintenance of the TRX-21 (1-speed
model) and TRX-22 (2-speed model) turbo liqui-
disers. The model reference and technical data
appear on the name plate attached to the
machine. These turbo liquidisers have been
designed and manufactured in accordance with
the following European directives:
· Machinery Directive 2006/42/EC.
· Low Voltage Directive 2006/95/EC.
· Electromagnetic
Compatibility
2004/108/EC.
· Directives 89/109/EEC and 90/128/EEC on
aluminium and plastic materials and articles in
contact with food.
· Arm mixers standard: UNE-EN 12854: 2004
· Protection level according to standard UNE-
EN 60529: Controls IP-55 and rest of the
machine IP-23
INSTALLATION
For optimum service and maintenance, please
follow these instructions.
MOVEMENT / INSTALLATION SITE
The turbo-liquisider is a mobile machine equip-
ped with wheels. When being moved take all
necessary measures to avoid blows, falls and
dangerous situations. Movement is recommen-
ded in the "transport" position.
When installing the machine make sure it is left
on a flat surface and with the rear wheels bloc-
ked. Also set the arm in a fixed position.
ELECTRICAL CONNECTION
Check that the machine's electrical charac-
teristics match the mains power supply.
TRX-21: 230-400V / 50 Hz / 3N (connected to
400V/3N); 220-380V / 60 Hz / 3N (connected to
220V/3). To change the voltage, refer to the
electrical diagram.
TRX-22: 400V / 50 Hz / 3N; 220V / 60 Hz / 3.
NOTE: The TRX-22 is single-voltage and it is
not possible to carry out any voltage change.
Prepare a wall-mounted socket that is always
accessible, with a general cut-off switch and a
EN
4
residual current and 4P, 10 A circuit breaker,
with its corresponding plug.
Rotation direction: The rotating blade (19) must
rotate anti-clockwise when looking from above
the tool. If the blade (19) rotates clockwise, to
reverse it swap two phases in the power cable.
POWER CABLE CHARACTERISTICS
The turbo-liquidisers are supplied with a 10 m
thermoplastic-sheathed power cable.
ATTENTION: THE EARTH CONNECTION IS
OBLIGATORY. DANGER OF ELECTROCU-
TION. The machine's earth wire is yellow-
green.
CONTROL FUNCTIONS: (Figure1)
"Start" button (A)
Directive
Pressing this button starts the motor if the arm
is within the work area and the timer is in posi-
tion.
"Stop" button (B)
Pressing this button stops the motor.
Speed selector (C). Only TRX-22
Position 0: Stops the motor, but it must be com-
pletely stopped with the "Stop" button. Never
leave the machine at "Position 0" without pres-
sing the "stop" button.
Position 1 low speed.
Position 2 high speed.
Timer (D).
Central position: Does not allow operation of
the machine.
Clockwise rotation: Timing from 0 to 60 minutes.
Anti-clockwise rotation: Continuous operation
without timer.
START-UP
WARNING:
Before using the machine for the first time,
clean the area in contact with food, the rota-
ting blade (19) and the fixed blade (18) with
(lukewarm) soapy water, rinse and leave to
dry.
Handle the rotating blade (19) and the fixed one
(18) very carefully because they have very
sharp edges.
ARM ROTATION AND BRAKING:
The arm (4) has a braking system, activated by
a lever (8) to block and and keep it at the des-
ired position. With the brake released the arm is
easily rotated. To block the arm turn the brake
lever (8) clockwise and tighten it firmly until the
arm is blocked. To release it turn it in the oppo-
site direction until the limit is reached (6).
DIFFERENT POSITIONS OF THE ARM:
Transport position: figure2
Tool change position: figure3
Storage position: figure 4

Work area: figure 5

ASSEMBLY AND DISASSEMBLY OF TOOLS
(FIGURE 6)
Description of the disassembly and assembly
process of the protector (17), Rotating blade
(19) and Fixed blade (18). These operations are
carried out during the cleaning or tool changing
processes.
Attention: Before undertaking any tool
assembly, cleaning, inspection or repair
work on the turbo liquidisers, the machine
must be unplugged from the mains.
The steps to fit the tools are described below. In
the "CLEANING" section the order of the steps
is the reverse of those described in this section.
- Unblock the brake with the lever (8), and rota-
te the arm (4) pushing the motor part down-
wards until the tool is accessible. Tool change
position figure2
- Insert the rotating blade (19) on the grooved
shaft and hold it until the fixing screw (20) is
screwed to the grooved shaft with the other
hand.
- Lock the rotating blade (19) using the wrench
supplied and tighten the fixing screw (20) with
the other wrench.
- Place the fixed blade (18) on the blade protec-
tor (17) so that the tabs of the fixed blade are
in position when inserting it in its slot.
- Insert the fixed blade + fixed blade support
assembly (18+17) in the arm holes (2) and
tighten the fasteners (21) until the support (17)
is fixed.
- Tighten the 3 screws (21) of the submersible
rod (2) with the wrench supplied with the
machine.

Publicidad