Victron energy BlueSolar PWM-Pro charge controller 12/24V Manual página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8. Battery related programming options
(see software manual or remote panel manual for details)
Battery related programming
options
Battery capacity setting (needed
for the internal battery monitor)
Over voltage load disconnect
Charge limit
Over voltage reconnect
Equalize
Absorption
Float
New charge cycle trigger voltage
Low voltage load reconnect
Under voltage warning reset
Under voltage warning
Low voltage load disconnect
Discharge limit
Equalize duration
Absorption duration
Multiply voltages by 2 for a 24V system
9. Day/night timing options
panel manual)
Gel
Sealed
(default
setting)
200Ah
16.0V
15.0V
15.0V
——
14.6V
14.2V
14.4V
13.8V
13.8V
13.2V
12.6V
12.2V
12.0V
11.1V
10.6V
——
2 hrs.
2 hrs.
2 hrs.
(see software manual or remote
Flooded
User
defined
1~9999
9~17V
9~17V
9~17V
14.8V
9~17V
14.6V
9~17V
13.8V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
9~17V
2 hrs.
0~3
2 hrs.
0~3
8