5. SPECIFICATIONS
BlueSolar PWM 48V
Battery Voltage
Rated charge current
Recommended solar array
Automatic low voltage load
disconnect
Maximum solar voltage
Self-consumption
Overload protection
Bulk charge**
Absorption charge
Float charge
Load disconnect
Load reconnect
Protection class
Terminal size
Weight
Dimension (h x w x d)
Mounting
Humidity (non condensing)
Operating temperature
Cooling
Safety
EMC
** The Controller immediately switches to the lower absorption voltage
level after the bulk charge level has been reached.
10A
20A
10A
20A
4x36 cell or 2x72 cell for 48V
Shut down after 60s in case of 130% load
Shut down after 5s in case of 160% load
Short circuit: immediate shut down
Settings
50,4V (manual)
52,4V (automatic)
Enclosure
6mm² / AWG10
95 x 140 x 33.5mm
Vertical wall mount
Max. 95%
-20°C to +50°C (full load)
Natural convection
Standards
IEC 62109-1
EN 61000-6-1, EN 61000-6-3
30A
48V
30A
Yes
100V
< 10mA
58,0V
56,8V
55,2V
44,8V
IP20
165gr
Indoor only
5