Guards (air motor cover, coupling shields, housings ...) have been designed for safe use of the
equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or damage to
property due to removal or patial removal of the guards
OPERATION TO CARRY OUT
Check earthings
Check leakage from the fittings
Check hoses
Operate the valves
Clean the pistons of the pumps (do not let the
material dry)
Check piston rod tightness
Check there is no leak at the upper cartridge
Check the cleanliness and the level of the T lubricant
Check the cleanliness of the strainer
Drain and replace the T lubricant
Caution : flush the pump for a long duration shutdown of the installation (more than two weeks)
Check the tightness of the piston rod
Check if the control system is clean
Check if the muffler(s) is clogged
Check that there is no air leakage
Check that air hoses are not damaged
Check that the connections between fittings and
hoses are correct
Check the correct condition of the supply hoses
(rubber, setting,...), regulators and gauges
Check the tightening of the components
Check the fixing of the cover
Check the correct operating of the safety valve(s)
D : daily
W : weekly
SAMES KREMLIN
D
W
GENERAL
X
X
X
PUMP
X
X
X
X
X
MOTOR
M : monthly
Q : quarterly
- 1 -
FREQUENCY
M
Q
H
X
X
X
X
H : half-yearly
Y : yearly
N° : 578.122.110-UK-1802
Y
X
X
X
X
X
X
X
X