Franklin Electric Little Giant 360 Guia De Inicio Rapido

Franklin Electric Little Giant 360 Guia De Inicio Rapido

Publicidad

Enlaces rápidos

Franklin Electric Co., Inc.
P . O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
INTRODUCTION
EN
This instruction sheet provides you with information required to safely own and
operate your Little Giant pump. It primarily covers the standard models of each
pump series. The form is applicable to other models in the series not listed by
catalog number in the replacement parts list section of the instruction sheet. If the
catalog number of your pump is not listed in the replacement parts list section,
then caution should be exercised when ordering replacement parts. Always give
the catalog number of your pump when ordering replacement parts.
The Little Giant unit you have purchased is of the highest quality workmanship and
material. It has been engineered to give you long and trouble-free service. The Little
Giant pumps are carefully packaged, inspected and tested to insure safe operation
and delivery. When you receive your pump, examine it carefully to determine that
there are no broken or damaged parts that may have occurred during shipment.
If damage has occurred, make notation and notify the firm that you purchased the
pump from. They will assist you in replacement or repair, if required.
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL,
OPERATE OR SERVICE THE LITTLE GIANT PUMP. KNOW THE PUMP
APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR
FUTURE REFERENCE.
DESCRIPTION
Your Little Giant pump is designed for general, commercial and industrial applica-
tions. It is designed for water, but is not submersible. It can be used to transfer
liquids, and to empty or fill tanks, sinks or bowls. The pump can be used to pump
bilge water, but the pump must not be located in the bilge area. It is self-priming to
7 ft. if the impeller is initially wet (primed). A carrying handle is included.
NOTE: Unit is NOT RECOMMENDED for use with soap detergents, gasoline,
waste oil, fuel oil, flammable, explosive or combustible liquids or other fluids not
compatible with pump component materials. Do not use unit in enclosed areas.
Intermittent duty only (15 minutes per hour).
SPECIFICATIONS
PUMP MODEL
Power Supply Volts
Power Supply Amps
Power Supply Hz (DC=12VDC battery)
Fuse
Max Fluid Temperature (°F)
Minimum Fluid Temperature (°F)
Thermal Protection (A=Autoreset)
Motor Max Current Rating (Amps)
Duty Cycle (I=Intermittent)15 min/hr
SAFETY GUIDELINES
WARNING: Do not use to pump flammable or explosive fluids such as gasoline, fuel
oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. Pump
should only be used with liquids compatible with pump component materials. Failure
to follow this warning can result in personal injury and/or property damage.
1. Know the pump application, limitations, and potential hazards.
2. WARNING: Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water.
3. The pump is not submersible and is intended for open-air use only.
4. Disconnect power before servicing a motor or its load. If the power discon-
nect is out-of-sight, lock it in the open position and tag it to prevent unex-
pected application of power.
5. Release all pressure within the system before servicing any component.
6. Drain all liquids from the system before servicing.
7. The pump motor is equipped with an automatic resetting thermal protector
and may restart unexpectedly. Protector tripping is an indication of motor
overloading as a result of operating the pump at low heads (low discharge
restriction), excessively high or low voltage, inadequate wiring, pumping
too hot a liquid, incorrect motor connections, or a defective motor or pump.
Read troubleshooting chart.
8. Do not touch an operating motor. Modern motors are designed to operate
at high temperatures.
PONY PUMP
MODEL 360, 365, 370
MODÈLE 360, 365, 370
MODELO 360, 365, 370
360/370
365
115V
12V
2A
10A
60
DC
2A
7A
140
140
40
40
A
A
1.6
7.0
I
I
9. Provide adequate protection and guarding around moving parts. Secure
the discharge line before starting the pump. An unsecured discharge line
will whip, possibly causing personal injury and/or property damage.
10. Check hoses for weak or worn condition before each use, making certain
that all connections are secure.
11. Periodically inspect pump and system components. Perform routine main-
tenance as required (see SERVICE INSTRUCTIONS).
12. Provide a means of pressure relief for pumps whose discharge line can be
shut-off or obstructed.
13. PERSONAL SAFETY: Wear safety glasses at all times when working with pum ps.
14. Do not add acid or electrolyte to a battery being used – add only water.
Consult the battery manufacturer for any additional safety instructions.
ELECTRICAL CONNECTIONS
1. Make certain that power source conforms to the requirements of your equipment.
2. When wiring an electrically driven pump, follow all electrical and safety
codes, as well as the most recent National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA) in the United States.
3. Model 360 and 370 are only for use on 115 volt (single-phase) and is
equipped with an approved 3-conductor cord and 3-prong, grounding-type
plug. Model 365 is for 12VDC.
4. To reduce the risk of electric shock, models 360 & 370 should be plugged
directly into a properly installed and grounded 3-prong grounding-type recep-
tacle. The green (or green and yellow) conductor in the cord is the grounding
wire. The motor must be securely and adequately grounded for your protec-
tion against shock hazards! Never connect the green (or green and yellow)
wire to a live terminal! SEE SECTIONS 10, 11 & 12 FOR MODEL 365.
5. Where a 2-prong wall receptacle is encountered, it must be replaced with
a properly grounded 3-prong receptacle installed in accordance with the
National Electrical Code and local codes and ordinances.
6. To ensure a proper ground, the grounding means must be tested by a
qualified electrician. Use only 3-wire extension cords that have 3-prong,
grounding-type plugs and receptacles that accept the equipment plug.
7. All wiring should be performed by a qualified electrician.
8. Protect electrical cord from sharp objects, hot surfaces, oil and chemicals. Avoid
kinking the cord. Replace or repair damaged or worn cords immediately.
9. When using an extension cord make sure wire is of adequate size to minimize
voltage drop at the motor. For models 360 & 370, 16 AWG is OK up to 40'.
Distance From
Power Source To 365
1 - 12 Ft.
13 - 24 Ft.
25 - 36 Ft.
For Model 365
10. The model 365 pump is not equipped with an inline fuse. Because of the
wide variety of applications and mounting situations, an inline fuse has not
been permanently installed. In order to provide adequate protection for the
motor, an inline fuse and fuse holder MUST be installed. The model 365
pump warranty does not cover motor damage caused by over heating. For
maximum protection, a fuse of 7 amps is suggested. Fuses and fuse holders
are readily available in most hardware, auto and home improvement stores.
11. GENERAL CONNECTION INFORMATION to a 12VDC battery.
a. Connect POSITIVE or PLUS (+) lead from the pump to battery first.
POSITIVE lead of pump is red.
b. If pump is to be connected to battery that is installed in a vehicle, con-
nect NEGATIVE or MINUS (–) lead to a ground away from the battery,
such as the metal of the vehicle or the negative wiring terminal strip or
other negative common point of the battery (away from the battery), if so
equipped. Always connect NEGATIVE (–) lead last. NEGATIVE (–) lead
of pump is black.
c. When DISCONNECTING — Disconnect NEGATIVE (–) lead from the
grounded location first. Then disconnect the POSITIVE (+) lead from the
battery.
12. When attaching pump leads to battery terminals, be sure that the area
(bilge of a boat, for instance) is adequately ventilated to prevent an explo-
sion or fire from explosive or flammable vapors that may be present.
a. Batteries emit hydrogen gas that is explosive. Avoid smoking, sparks or
open flame anywhere in the vicinity of the battery.
b. EXPLOSION from battery can cause blindness. Shield eyes when work-
ing near any battery.
c. Batteries contain sulfuric acid. In case of contact with eyes, skin or cloth-
ing FLUSH IMMEDIATELY WITH LARGE AMOUNTS OF WATER; GET
MEDICAL ATTENTION.
Recommended
Wire Size
#14
#12
#10
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant 360

  • Página 1 10. Check hoses for weak or worn condition before each use, making certain MODEL 360, 365, 370 Franklin Electric Co., Inc. that all connections are secure. P . O. Box 12010 MODÈLE 360, 365, 370...
  • Página 2 INSTALLATION 2. Always drain pump when not in use. WARNING: In any installations where property damage and/or personal 3. If pump is not going to be used for a month or longer, flush with fresh water injury might result from an inoperative or leaking pump due to power out- and remove body cover, take impeller out, clean inside body and apply ages, discharge line blockage, or any other reason, a backup system(s) generous coating of Vaseline, to both inside body and impeller before...
  • Página 3: Directives De Sécurité

    DIRECTIVES DE SÉCURITÉ 9. Utiliser des câbles de diamètre adapté pour minimiser la chute de tension au moteur. Pour les modèles 360 et 370, le 16 AWG est acceptable jusqu’à 12,2 m (40 pi). La Distance de la Grandeur Métallique AVERTISSEMENT : Ne pas utiliser pour pomper des liquides inflammables Source de Pouvoir à...
  • Página 4: Introducción

    9. Installez un clapet de pied et amorcez la pompe lorsque la hauteur de f. Aligner le plat sur l’intérieur du raseur d’arbre de roue avec le plat sur pompage est supérieure et longeur à 1,8 mètre. l’arbre de moteur. Pousser le roue à sa place, en tordant les camionnettes de roue dans une rotation dans le sens des aiguilles d’une montre.
  • Página 5: Seguridad Personal

    6. Drene todos los líquidos del sistema antes de darle mantenimiento. vo o con otro punto común negativo (–) de la batería (alejado de la batería), si ésta está equipada de tal modo. Siempre conecte el cable NEGATIVO (–) 7. El motor de la bomba está equipado con un dispositivo automatico de por último.
  • Página 6 2. Se puede encender y apagar la unidad conectando o desconectando el 3. Si no piensa utilizar la bomba durante un mes por lo menos, limpiela con enchufe a la toma de corriente de 115V. agua potable. Luego drene el agua y retire la tapa del cuerpo de la bomba, quite el impulsor, limpie el interior del cuerpo, y aplique una capa de pet- 3.
  • Página 7 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT DÉFECTEUX PROBABLE CAUSES • CAUSES PROBABLES CORRECTIVE ACTIONS • SOLUTIONS • SOLUCION • PROBLEMA • CAUSAS PROBABLES No power or incorrect voltage • Aucune électricité ou aucune Supply correct voltage •...
  • Página 8: Garantie Limitée

    (avec différentes longueurs de fil) et nous recomman- Form 998230 - 04/2008 dons que chaque pompe soit reliée à un interrupteur de ce type. ©2008 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Este manual también es adecuado para:

Little giant 365Little giant 370

Tabla de contenido