Chapter 3
Tab. 1:
Enable zone and
safe switch off
distance
IN30-E0407K
Tab. 2:
Enable zone and
safe switch off
distance
IN30-E0305K
60
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Product description
Material
Steel FE360
Stainless
steel 1.4302
(V2A)
AlMg 3G22
CuZn 37
Cu
Material
Steel FE360
Stainless
steel 1.4302
(V2A)
AlMg 3G22
CuZn 37
Cu
IN30-E0407K
(cylindrical M12)
Enable zone
Lower limit
Upper limit
0.5 mm
4 mm
0 mm
3.1 mm
0 mm
1.8 mm
0 mm
2.0 mm
0 mm
1.2 mm
IN30-E0305K
(cylindrical M18)
Enable zone
Lower limit
Upper limit
1.0 mm
8.0 mm
0.5 mm
5.6 mm
0 mm
3.2 mm
0 mm
3.2 mm
0 mm
2.4 mm
Operating instructions
IN3000 Direct
Safe switch
off distance
6 mm
Safe switch
off distance
12 mm
8014173/YIJ3/2016-04-18