Layout; Intended Use; Technical Data - Parkside PSE 2800 B2 Instrucciones De Utilización Y De Seguridad

Generador eléctrico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Safety Information
can vary from country to country. Nevertheless,
this information makes it possible for the user to
be able to make a better assessment of the
dangers and risks involved.
IMPortAnt: Use only normal, unleaded
petrol as fuel.
read all the safety regulations and instruc-
tions. Any errors made in following the safety reg-
ulations and instructions may result in an electric
shock, fire and/or serious injury.
keep all safety regulations and instructions
in a safe place for future use.
Layout (Fig. A - M)
Tank indicator
1
Tank cover
2
2 x 230 V ~ socket-outlets
3
Earth connection
4
Overload cut-out
5
Voltmeter
6
Oil filler screw
7
Oil drainage screw
8
Oil deficiency protection for low oil switch-off
9
On/Off switch
10
Choke lever
11
Reversing starter
12
Petrol cock
13
Wheels
14
Axle
15
Foot
16
Push bar holder
17
Push bar
18
Screws size M8 x 40
19
Screws size M8 x 16
20
Washers for wheels
21
Securing split pins for wheels
22
Nuts M8
23
Screwdriver
24
Spark plug wrench
25
44 GB/MT

Intended use

The device is designed for applications operated
with a 230 V alternating current source.
Be sure to observe the restrictions in the safety
instructions. The generator is intended to provide
electric power tools and light sources with electricity.
When using the device with household appliances,
please check their suitability in accordance with
the relevant manufacturer's instructions. In case of
doubt, ask an authorized dealer of the respective
equipment.
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user/operator and not the manufacturer
will be liable for any damage or injuries of any
kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or industrial
businesses or for equivalent purposes.

technical data

Generator:
Protection type:
Continuous rated power
Prated (S1):
Maximum power Pmax
(S2 2 min):
Rated voltage Urated:
Rated current Irated:
Frequency Frated:
Drive engine design:
Displacement:
Fuel:
Tank capacity:
Engine oil:
Synchronous
IP23M
2600 W
2800 W
2 x 230 V ~
11.3 A
50 Hz
4-stroke, air-cooled
208 cm³
Petrol
15 l
approx. 0.6 l
(15W40)

Publicidad

Tabla de contenido
loading

Tabla de contenido