Troubleshooting Guide; Maintenance Schedule - Parkside PSE 2800 B2 Instrucciones De Utilización Y De Seguridad

Generador eléctrico
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

troubleshooting guide

Fault
Cause
Engine does
Automatic oil
not start
cut-out has not
responded
Spark plug
fouled
No fuel
Generator
Controller or
has too little
capacitor
or no voltage
defective
Overcurrent
circuit-breaker
has triggered
Air filter dirty
Before each
use
Checking the
X
engine oil
Changing the
engine oil
Checking the
X
air filter
Cleaning the
air filter
Cleaning the
petrol filter
Visual inspec-
X
tion of the
equipment
Troubleshooting guide / Maintenance schedule
Please adhere to the following maintenance
remedy
periods in order to ensure a failure-free operation.
Check oil level,
top up engine oil
IMPortAnt! the equipment must be
filled with engine oil and fuel before it
Clean or replace
is started.
spark plug
(electrode
spacing 0.6 mm)
Refuel / have
the petrol cock
checked
Contact your
dealer
Actuate the
circuit-breaker
and reduce the
consumers
Clean or replace
the filter
After an
After an
operating
operating
period of
period of
20 hours
50 hours
For the first
time, then every
50 hours

Maintenance schedule

After an
operating
period of
100 hours
X
X
X
After an
operating
period of
300 hours
Change the
filter insert if
necessary
GB/MT
49

Publicidad

Tabla de contenido
loading

Tabla de contenido