Sammic DA-12 Instrucciones página 12

Descalcificador automático
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

english
clockwise till it reaches the brine and rinse (III)
position and make sure that there is no more wa-
ter under pressure coming out from the drain.
• Uscrew the parts 7F and 8F with a screwdriver
(fig. 9).
• Put a rigid stick with a diameter of about 4 mm
and 30 cm long into the hole to insert part 7F
and push it until its opposite side comes out
from the injector (28 F).
• Clean the three pieces and make sure that the 1.5
mm injector hole is completely free. This is fun-
damental to ensure a correct suction of the salty
water in the pickle.
• Reassemble the parts correctly and open slowly
the water once again; connect the plug to the
socket and set again the timer, if necessary.
PROBLEM
The valve does not regenerate by
itself
The valve regenerates at the wrong
time
Pickle is not sucked
The pickle vat fills too much
Water softener salt consumption is
higher or lower than estimates
Intermittent or irregular pickle suction • insufficient feeding pressure
After regeneration, the water is not
softened
12
• Turn the button (always counterclockwise) on
the brine refill and purge (IV) position for
about 2 minutes. Turn again the red push button
onto brine and rinse (III) and make sure that
water suction from pickle is correct.
7. Troubleshottings guide
• Experience shows that 90% of bad functioning of
water softeners is caused by bad installations of
the draining pipe. For this reason, the manufactu-
rer recommends a rigid pipe with an internal dia-
meter of at least 8 mm.
• Before applying the water softener, it is suggested
to install a mechanical filter so as to prevent sub-
stances such as earth from seeping into the water
softener.
CAUSE
• disconnected power
• faulty timer engine
• weekly disk not programmed
• uncorrect timer regulation
• insufficient operating pressure
• clogged unloading pipe
• clogged injector
• in valve blocked in open
• the ball in the glass (fig. 3) has
blocked too early
• pickle valve does not close
• too much water passing during
pickle recycling
• air suction into the pipe connecting
to pickle vat
• adjustment default
• the set days for regeneration are too
many or insufficient
• dirty or faulty injector
• drain is not completely free
• the water softener has not
regenerated
• lack of salt in the pickle
• the mixer is too open
Automatic Water Softeners MINI and MAXI
SOLUTIONS
• connect it
• replace it
• program it
• check if the programmed time is
correct
• make sure to have at least 2 bar
• make sure unloading pipe is free
• clean 8F and 28 F injector (fig. 9)
• manually operate the valve with a
screwdriver (fig. 10)
• check that the connection between
glass and pickle has a good sealing
• manually operate with a perfectly
screwdriver to remove possible
impurities (fig. 10)
• decrease the calibrate value on the
1F pickle regulator (fig. 9)
• check if the connection between
the glass and the pickle is still
good sealing
• make a new adjustment on 1F
• check the metal bars in timer
setting
• make sure to have at least 2 bar
• clean parts 8F and 28F,
(fig. 9)
• make sure draining pipe is free
• make sure that electric power is
being
• check timer input
• fill up the pickle
• check the correct mixer opening
(fig. 8 - VI)
Instruction leaflet and warnings for water softeners

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Da-26

Tabla de contenido