Haier HAVG6 Instrucciones De Uso página 85

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
TABLE FRONTAL PVUH75MF
Gas Type
Gas Pressure
Burners
Max (kW)
Min (kW)
AUX
1
SR
1,5
SR
1,75
R
2,7
NG 4,2
DC 4,2 kW MONO
LPG 4
NG 5
DC 5 kW MONO
LPG 4,6
Gas Categories
G20/G25 20/25mbar 2E+
G30/G31 28-30/37mbar 3+
Countries
II2H3B/P
G20 20mbar 2H
Gas Categories
G30/G31 50/50mbar 3B/P
Countries
SINGLE BURNER EFFICIENCY
AUX
-
G20
G20
20 mbar
25 mbar
Injector NG
Injector NG
Max - Min
Max - Min
72X
70X
0,3
(1kW-0.3kW)
(1kW-0.3kW)
85Y
85Z
0,5
(1.5kW-0.5kW)
(1.5kW-0.5kW)
97Z
91Z
0,5
(1.75kW-0.5kW)
(1.75kW-0.5kW)
112Y
110F3
0,8
(2.7kW-0.8kW)
(2.7kW-0.8kW)
155H3
148H3
2,4
(4,2kW-2.3kW)
(4,2kW-2.3kW)
166S4
160H3
2,4
(5kW-2.3kW)
(5kW-2.3kW)
II2E+3+
G20 20mbar 2H
G30/G31 28-30/37mbar 3+
BE,FR
CY,CZ,GB,GR,IE,IT,PT,SI,ES,TR,CH BG,HR,DK,EE,FI,LV,LT,NO,RO,SK,SE,CZ,SI,TR
II2EK3B/P
G20 20mbar 2E
G25.3 25mbar 2K
G30/G31 30/30mbar 3B/P G30/G31 30/30mbar 3B/P
AT,CH
NL
Efficiency Decleration 2016/426
PVUH60MF - BIG FRONT (L1)
SINGLE BURNER EFFICIENCY
AUX
SR
R
-
57%
54.3%
MEDIUM %54.7
PVUH75MF - 4+1 (L3)
SR
SR
R 1.5 kW DC 5 kW
60%
60%
54.3%
MEDIUM %58
TECHNICAL INFORMATION 3
G25.1
G25.3
25 mbar
25 mbar
Injector NG
Injector NG
Max - Min
Max - Min
74F1
72F1
(1kW-0.3kW)
(1kW-0.3kW)
91Y
95F2
(1.5kW-0.5kW)
(1.5kW-0.5kW)
98Y
102F3
(1.75kW-0.5kW)
(1.75kW-0.5kW)
120F2
115F2
(2.7kW-0.8kW)
(2.7kW-0.8kW)
154F3
148F3
(4,2kW-2.3kW)
(4,2kW-2.3kW)
168F3
162F3
(5kW-2.3kW)
(5kW-2.3kW)
II2H3+
II2HS3B/P
G20 20mbar 2H
G25.1 25mbar 2S
HU
PVUH60MF - DIAMOND (L2)
SINGLE BURNER EFFICIENCY
DC 4,2 kW
AUX
52.8%
-
PVUH75MF - CENTRAL (L4)
SINGLE BURNER EFFICIENCY
AUX
SR
59.4%
-
60%
G30/G31
G30/G31
28-30 mbar
Injector LPG
Injector LPG
Max - Min
Max - Min
50
(73g/h-22g/h)
(73g/h-25g/h)
62H2
(109g/h-36g/h)
(109g/h-40g/h)
65
(127g/h-36g/h)
(127g/h-40g/h)
83
(196g/h-58g/h)
(196g/h-62g/h)
100
(286g/h-153g/h)
(286g/h-160g/h)
107
(334g/h-153g/h)
(327g/h-160g/h)
II2H3B/P
G20 20mbar 2H
G30/G31 30/30mbar 3B/P
II2E3B/P
G20 20mbar 2E
G30/G31 37/37mbar 3B/P G30/G31 50/50mbar 3B/P
PL
SR
R
DC 5 kW
60%
54,3%
59.4%
MEDIUM %57.9
R 1.75 kW R 1.75 kW DC 5 kW
54.3%
54.3%
MEDIUM %57
G30/G31
37 mbar
50 mbar
Injector LPG
Max - Min
46
46H2
(73g/h-29g/h)
57
56M
(109g/h-44g/h)
61
58M
(127g/h-44g/h)
78
73S
(196g/h-69g/h)
94
78 F4
(286g/h-175g/h)
100
95 type 6
(327g/h-175g/h)
II2E3B/P
G20 20mbar 2E
DE
59.4%

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Havg7Hahg6Hahg7Hahg7w5xhHahg6d5xhHavg75hbpb

Tabla de contenido