2.
Most heating blankets are available with an optional high-limit safety thermostat to protect
both the heater and the product being heated from damage if the main controlling device
fails. This option is especially recommended for surfaces that are high risk for heat damage
(e.g. plastic). Contact factory for more details.
3.
Ensure heater is protected by a properly rated circuit breaker or fuse.
4.
Use of a ground fault circuit interrupter (GFCI) is highly recommended and may be required
according to local electric code.
5.
Power lead wires should be connected to the power source (or temperature control device)
directly, through a junction box, or to a connector that is mated to a receptacle connected to
®
the power source. BriskHeat
Heating Blankets are non-polarized, allowing either power
lead wire to be connected to the neutral or hot. The third wire (if applicable), designated by
the color green (or a green stripe), should be connected to ground. For three phase
installation, contact the factory.
6.
SRX series: The conduit connection is 3/4" hub.

TROUBLESHOOTING GUIDE

Please read this guide prior to contacting BriskHeat
commonly asked questions. If you are unable to identify the problem or need additional
assistance, please contact your local distributor/ representative or us at
1-800-848-7673, 614-294-3376, or bhtsales1@briskheat.com.
PROBLEM
SOLUTION(S)
Heater does not warm up
Verify heater is connected to proper voltage.
Check to see if there is a resistance reading (not an open circuit)
in heater using an ohm meter.
Pressure sensitive
Verify date of manufacture. PSA has a shelf life of 6 months.
adhesive is not adhering
Ensure there are no air gaps and heater is making intimate
contact with surface being heated. Use a medium to hard rubber
roller.
Circuit breaker is tripping
Validate that the circuit breaker is capable of handling the amp
requirement of heater. The identification label located on the
power cord displays the heater's amperage requirement.
Examine heater and cord for any damage.
Check to see if there is a resistance reading between power
leads and the ground lead.
®
© BriskHeat
Corporation. All rights reserved.
SRL, SRP, SRMU, SRX, Custom Series
Silicone Rubber Heating Blankets
®
. This guide is designed to answer the most
7

WARRANTY INFORMATION

BriskHeat warrants to the original purchaser of this product for the period of eighteen (18) months
from date of shipment or twelve (12) months from date of installation, whichever comes
first. BriskHeat's obligation and the exclusive remedy under this warranty shall be limited to the
repair or replacement, at BriskHeat's option, of any parts of the product which may prove
defective under prescribed use and service following BriskHeat's examination, is determined by
BriskHeat to be defective. The complete details of the warranty can be found online at
www.briskheat.com or by contacting us at 1-800-848-7673 (toll free, U.S. / Canada) or
1-614-294-3376 (Worldwide).
4800 Hilton Corporate Dr. Columbus, OH 43232
Toll Free: 800-848-7673
Phone: 614-294-3376
Fax: 614-294-3807
Email: bhtsales1@briskheat.com
®
© BriskHeat
Corporation. All rights reserved.
SRL, SRP, SRMU, SRX, Custom Series
Silicone Rubber Heating Blankets
8

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Srp serieSrmu serieSrx serieCustom serie

Tabla de contenido