MAINTENANCE INSTRUCTIONS

Anyone who reads and understands these instructions is
qualified to maintain this heater.
Maintenance:
All maintenance should be performed after heater has cooled to room temperature and with the
electricity disconnected.
This product should be inspected prior to being installed and at least every 12 months during use.
Dirt, oil, grease or other foreign matter can be removed with a damp rag and mild household
cleaners.
Do not attempt to repair a damaged heater.
Inspection:
Inspection should be performed after the heater has cooled to room temperature and with the
electricity disconnected.
The heater should be free of any cuts, cracks, or punctures.
The power leads should not have any visible breaks in their insulation
The heater should be free of any build-up of dirt, oil, grease, or other foreign matter.
Storage:
This product should be stored indoors.
Disposal:
This product does not contain any hazardous substances and may be discarded with domestic
waste.
®
© BriskHeat
Corporation. All rights reserved.
SRL, SRP, SRMU, SRX, Custom Series
Silicone Rubber Heating Blankets
9

TROUBLESHOOTING GUIDE

Please read this guide prior to contacting BriskHeat
commonly asked questions. If you are unable to identify the problem or need additional assistance,
please contact your local distributor/ representative or us at 1-800-848-7673, 614-294-3376, or
bhtsales1@briskheat.com.
PROBLEM
SOLUTION(S)
Does not heat
Verify heater is connected to proper voltage. The identification label located on
the power cord displays the heater's voltage requirement.
Using an ohm meter, check to see if there is a resistance
reading (not an open circuit) in the heater.
If external temperature controlling device is installed, ensure the heaters
control dial is in the maximum heating position.
Pressure sensitive
Verify date of manufacture. PSA has a shelf life of 6 months.
adhesive is not
Ensure there are no air gaps and heater is making intimate contact with
adhering
surface being heated. Use a medium to hard rubber roller.
Circuit breaker is
Validate that the circuit breaker is capable of handling the amp requirement of
tripping
heater. The identification label located on the power cord displays the heater's
amperage requirement.
Examine heater and cord for any damage.
Check to see if there is a resistance reading between power leads and the
ground lead.
®