figure 28
2 Every week: make sure the auger seal is not worn or
damaged. If it is, replace with an original spare part from the
manufacturer. (see figure 29)
figure 29
3 Every week: check for auger seal leaks by examining the
drain tray (see figure 30). In case of a leak, make sure the
auger seal is properly installed and not worn or damaged. If it
is, replace with an original spare part from the manufacturer
(see figure
29).
figure 30
4 Every Month: eliminate any dust that has built up on the
condenser filter situated at the back of the machine. (see figure
31)
ATTENTION
Be careful with the condenser fins as they are sharp.
5 In case of strange noise or failure, disconnect the machine
from the power source and call for service.