Selecting powerful domestic water heating operation
1
Press
v
for 5 seconds to activate powerful domestic water
heating operation.
Icons
w
and
m
start flashing.
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (
1
Use the
s
button to activate quiet mode operation (
Icon
s
appears on the display.
If the controller is set in permission level 2 or 3 (refer to "Field
s
settings" on page 10), the
Selecting weather dependent set point operation (only in
heating mode)
1
Press the
ba
button to select weather dependent set point
operation.
Icon
a
appears on the display as well as the shift value. The
shift value is not shown in case it is 0.
2
Use the
bi
and
bj
buttons to set the shift value.
Range for the shift value: –5°C to +5°C
Displaying actual temperatures
1
Push the
ba
button for 5 seconds.
The
b
icon and the outgoing water temperature are displayed.
The icons
l
and
=
are flashing.
2
Use the
pi
and
pj
buttons to display:
•
The outdoor temperature (
•
The domestic hot water tank temperature (
flashing).
•
The outgoing water temperature (
If no button is pressed for 5 seconds, the controller leaves the
display mode.
Schedule timer operation
In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.
The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to "Manual operation" on page 5). The schedule timer will regain
control over the installation as soon as the next programmed
command of the schedule timer occurs.
p
The schedule timer is enabled (
not displayed), by pressing the
pr
NOTE
Only use the
schedule timer. The schedule timer overrules the
y
button. The
schedule timer until the next programmed action.
If the auto restart function is disabled, the
schedule timer will not be activated when power
returns to the unit after a power supply failure.
Press the
pr
again.
When power returns after a power supply failure,
the auto restart function reapplies the user
interface settings at the time of the power supply
failure.
It is therefore recommended to leave the auto
restart function enabled.
R(D/B)LQ011~016AA6V3+W1
Unit for air to water heat pump system and options
4PW53150-1
s
)
s
).
button will not be operable.
u
icon is flashing).
w
icon is
=
are flashing).
p
icon displayed) or disabled (
button.
pr
button to enable or disable the
y
button only overrules the
button to enable the schedule timer
The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to "Setting the clock" on page 4.
Manually adjust the clock for summertime and
wintertime. Refer to "Setting the clock" on page 4.
A power failure exceeding 1 hour will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to "Setting the clock" on page 4 to adjust the clock
and the day of the week.
The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.
To set up the SCHEDULE TIMER refer to chapter "Programming and
consulting the schedule timer" on page 7.
What can the schedule timer do?
The schedule timer allows the programming of:
1.
Space heating and space cooling (refer to "Programming space
cooling or space heating" on page 8)
Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Five
actions per weekday can be programmed, totalling 35 actions.
NOTE
When the unit is connected to an external room
thermostat, the schedule timer for space cooling and
space heating is overruled by the external room
thermostat.
2.
Quiet mode (refer to "Programming quiet mode, booster heating
or domestic water heating" on page 9)
Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.
3.
Booster heating (refer to "Programming quiet mode, booster
heating or domestic water heating" on page 9)
Allow or disallow booster heating at a scheduled time. Five
actions can be programmed per mode. These actions are
repeated daily.
4.
Domestic water heating (refer to "Programming quiet mode,
booster heating or domestic water heating" on page 9)
Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.
The programmed actions are not stored according to
their timing but according to the time of programming.
icon
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.
When the schedule timer switches space heating or
space cooling
switched off. Note that this has no influence on
domestic water heating.
x
, the controller will also be
Operation manual