Translation of the original instructions
6
The copper base has 4 slots and is dedi-
cated to M4 studs
Screw for adjusting the stud's position.
4
The pin must be perpendicular to the sheet.
5
Do not press too much to not overwrite the nipple. Only the stud is in contact with the sheet.
The base must come out by approximately 1mm from the extremity of the mandrel.
6
A wheel with index
7
THERMAL PROTECTION
The machine is provided with an automatic thermal protection system, which will stop the machine to prevent it from
overheating. When the Thermal Protection Indicator illuminates (fig.I-5 - II-5), let the machine cool down.
MAINTENANCE
• Ensure the machine is unplugged, and that the ventilator inside has stopped before carrying out maintenance work.
(DANGER High Voltage and Currents).
• Maintenance should only be carried out by a qualified person.
• GYS recommends removing the steel cover 2 or 3 times a year to remove any excess dust. Take this opportunity to
have the electrical connections checked by a qualified person with an insulated tool.
• Regularly check the condition of the power supply cord. If damaged, it will need to be replaced by the manufacturer,
its' after sales service or a qualified person.
SAFETY
Spot welding can be dangerous and can cause serious and even fatal injuries.
Protect yourself and others. Ensure the following safety precautions are taken:
Arc radiation
Rain, steam, damp
Burns
Fire risks
Electric shocks
Fumes
Falls
GYSPOT COMBI 230 E PRO
4
allows adjusting the compression of the spring.
8
Protect yourself with a helmet fitted with filters in compliance with EN169 or EN
379.
Use your welding unit in a clean/dry environment (pollution factor ≤ 3), on a flat
surface, and more than one meter from the welding work-piece. Do not use in
rain or snow.
Wear protective (fire-proof) clothing (cotton, overalls or jeans).
Wear protective gloves and a fire-proof apron.
Ensure other people keep a safe distance from the work area and do not look
directly at the welding arc.
Protect others by installing fire-proof protection walls.
Remove all flammable products from the work area. Do not work in presence of
flammable gases.
This device must only be used with an earthed power supply. Do not touch the
parts under tension. Check that the power supply is suitable for this unit.
Do not inhale welding gases and fumes. Use the device in a well ventilated
environment, with artificial extraction if welding indoors.
Do not move the unit over people or objects.
5
Automatic gun without trigger
EN
8
7
17