4. Operation
The room temperature is regulated using the infinitely
adjustable thermostat (A).
If the rotary knob is set to the lowest setting i.e. to the extreme
left, the thermostat switches the heating device on at an
ambient temperature of approx. 10° C.
When the thermostat switches on, the red lamp lights up (B).
Note!
Rooms can become overheated if left unattended whilst being
heated; this depends on the size of the room, its heating
requirements and the setting of the thermostat. Persons who
are not able to vacate the room if the temperature becomes too
high can thus be placed in danger.
5. Protection Against Overheating
If the permissible temperature is exceeded, the heating device
switches off automatically. If this occurs, pull the mains plug out
and leave the device unplugged for a few minutes so that the
temperature limiter can switch back again.
Then remove the cause, e.g. when the air grid is blocked or
covered. When the device has cooled sufficiently, it can be
started up again.
6. Faults
If the heating device does not give off heat, check the following
points:
• Has the thermostat been set to the desired temperature?
• Has the overheat protection been triggered? See chapter 5!
• Is the fuse in the fuse box switched on?
If you cannot remedy the fault, please contact your retailer.
If required, you can also address your queries to the service
hotline of Glen Dimplex Deutschland GmbH.
Tel: +49 (0) 9221 709-564
Fax: +49 (0) 9221 709-589
To process your order, please state the device type as well as
its production number (E No.) and production date (FD). This
information is listed on the type plate.
Repairs and corrective measures must only be carried out by a
qualified electrician or by your after-sales service.
7. Cleaning
To clean the device, first disconnect it from the mains and allow
it to cool down. Clean the outside of the unit using a soft, damp
cloth. Do not use scouring powder or furniture polish as this
may damage the surface. Dust which gathers inside the device
can be removed from the outside using a vacuum cleaner.
8. Technical Data
Heat output:
Connection voltage:
Degree of protection:
Safety class:
Dimensions (W x H x D): 260 x 242 x 121 mm
Weight:
9. Warranty
This product is supplied with a two-year warranty according to
our terms of guarantee.
10. Note on Disposal
Do not dispose of the unit with general household
B
waste. The device must be taken to a local waste
disposal plant.
A
Glen Dimplex Deutschland GmbH
Am Goldenen Feld 18, 95326 Kulmbach, Germany
www.dimplex.de
kundendienst.hauswaerme@dimplex.de
4
600 W
1/N/PE~, 230 - 240 V
IP20
I (with protective conductor)
1.1 kg
fw550-en_ba 12/09/B