● Press the button
● With the button
● With the button
● Press the button
NOTE:
● The setting will be interrupted if the user performs no action in 10 seconds during setup. It will be
back to the main menu automatically
For example,
The thermostat can calibrate the true temperature to avoid the temperature difference. Check with the actual
temperature with the thermometer. For any temperature difference you can go:
● Press the button
● With the button
● With the button
● Press the button
THE DETAILS OF ADVANCE SETTINGS,
Indicator
Description
number.
A1
Return difference value Δt range
A2
Temperature calibration range
A3
Operation mode
A4
NTC Sensor type
A5
The maximal temperature value range setting
A6
The minimum temperature value range setting
A7
Alarm setting
A8
Programming mode
A9
Mode choice
AA
Factory default setting

ADVANCED SETTING

for around 3 seconds then it entries into the advanced setting.
to choose the different settings.
and
to change the value of the setting accordingly.
to save the setting.
for around 3 seconds, then it entries into the advanced setting.
to select A2.
and
to change the value of the actual temperature on the thermometer.
to save the setting.
EN
Parameter value
0.5 ~ 2.5°C
±9°C (from the actual temperature value)
00: cooling mode 01: heating mode
01: single sensor
20 ~ 70°C
1°C ~ 10°C
00: cancel alarm
01: display alarm only
02: alarm symbol and the buzzer alarm
0: 5+2
1: 6+1
2: 7
0: manually;
1: automatic mode
88: no meaning
00: resume the factory default settings
7
KEN001THEFUL
v1a • 09.12.2020
Setting
1
-1
01
01
35°C
5°C
02
0
0
88