● Press the button either
● As soon as the SV value blinks, you can revise the value by pressing the button
● Press the button
NOTE:
● The setting will be interrupted if the user performs no action in 5 seconds during setup. It will be back
to the main menu automatically.
HEATING MODE SETTING:
Load output indicator lamp (red) turns on, when true temperature PV = (Setting temperature SV + Return
difference value Δt), and vice versa.
For example,
a. PV = (Setting temperature SV + Return difference value Δt)
SV 18°C + 1°C (default setting at A1)
PV 18°C
Load output indicator lamp (red) turns on.
b. PV = (Setting temperature SV + Return difference value Δt)
SV 18°C + 1°C (default setting at A1)
PV 19°C
Load output indicator lamp (red) turns off.
COOLING MODE SETTING:
Load output indicator lamp (red) turns on, when true temperature PV = (Setting temperature SV + Return
difference value Δt), and vice versa.
For example,
a. PV = (Setting temperature SV + Return difference value Δt)
SV 18°C + 1°C (default setting at A1)
PV 19°C
Load output indicator lamp (red) turns on.
b. PV = (Setting temperature SV + Return difference value Δt)
SV 18°C + 1°C (default setting at A1)
PV 18°C
Load output indicator lamp (red) turns off.
ALARM:
Don't put the NTC sensor close to fire or in any well-ventilated areas to avoid the alarm.
The thermostat buzzers (only when the setting at A7 is 02 in the parameter setting)
a. High temperature alarm at heating mode (HI)
PV ≥ SV + 3°C (default setting at A1)
PV displays HI and blinks, then triggers the alarm.

TEMPERATURE SETTING

or
.
to save the setting.