ATTENTION: PRESSURE REQUIREMENTS
Max. inlet water pressure: 0.345 MPa (3.45 bar) (50 psi)
Min. inlet water pressure: 0.138 MPa (1.38 bar) (20 psi)
INTRODUCTION
The following instructions cover the installation of a
220 VAC, 50/60 Hz (international) booster. An appropriate
3-wire power receptacle must be located within 6 ft (1.8 m)
of the Booster Kits.
Unpack the unit from its transportation packaging and
visually check for any signs of damage.
NOTE: Do not plug in Booster Pump Module at this time.
Installation
IImortant
This booster pump is intended to be installed outside
zone 1 and 2, as specified in IEC 60364-7-701.
The booster pump needs to be installed with a horizontal
distance to possibly spraying water of 1.8 meter. It is not
allowed to install the water booster above or below
(vertically) of possibly spraying water sources.
The water booster has to be installed vertical and NOT
horizontal.
PREPARING THE POWER CORD/MAINS LEAD
(INTERNATIONAL UNITS ONLY [P.N. 00216382])
IImortant
The wires in the power cord/mains lead are colored in
accordance with the following code:
Green / Yellow = Ground/Earth
Blue = Neutral
Brown = Line/Live
1. Locate a 3-terminal plug. This plug (not furnished with
kit) must have a ground-wire-connecting terminal.
2. Locate the loose end of the power cord attached to
the kit. All three (3) wires are stripped to 1/2" (1.3 cm)
length from the end.
3. Connect all three (3) wires to the plug using the
1/2" (1.3 cm) stripped ends or any other terminal
requirements. Different plugs and terminals may
require different stripped lengths.
4. Inspect the cord and plug connection for any loose or
bare wires.
2 of 32
Part Number 020006830 04/23/2018
Subject: Installation Procedure Model WBK10X Water Booster Pump

GROUNDING INSTRUCTIONS

The Multiplex Model WBK10X Water Booster Pump should
be grounded/earthed. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electrical current. This
product is equipped with a cord having a grounding/
earth wire with an appropriate grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
Risk of Electric Shock
This kit is supplied with a ground conductor and
grounding-type attachment plug (domestic only). To
reduce the risk of electric shock, be certain that it is
connected only to a properly grounded, grounding-
type receptacle.
NOTE: For 220-240 VAC, 50/60 Hz International Units, a
ground male plug must be supplied at the installation of
the booster pump.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood or
if in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
Do not use an extension cord or an adapter plug with this
equipment.