Recommended Wiring Practices
1. For best grounding practices, isolate pin 7, supply ground, from pins
3 and 5, command, +5Vdc reference, and output grounds.
2. Use twisted or twisted shielded-pair cable for CAN per the applicable
standard.
3. Confirm that the CAN network is properly terminated using 120-Ω
resistors.
4. Make certain that the harness is designed and constructed to minimize
induced interference resulting from EMI coupling between signal wires.
5. Keep high-voltage AC cables separate from low-voltage DC signal and
supply cables.
6. Check ALL wire connections to and from this unit to ensure NO short or
open circuits are present.
7. Ensure that any unused wires/connections are terminated safely and not
shorted together.
8. Isolate the amplifier if any battery charging or battery boosting takes
place on the installation.
9. Follow and abide by all applicable health and safety standards – protect
yourself and others.
10. Never disconnect or connect wires to or from this unit unless it is isolated
from the power supply.
11. Use best practice wiring standards.
A 10A ATC or ATO fuse is required to be installed ahead of the
equipment.
In order to avoid damage to the product, ensure that all electrical
connections are fully disconnected from the XMD driver prior to
welding on the machine.
www.sunhydraulics.com
© 2017 Sun Hydraulics Corporation
Pub.#999-901-853 November 2017