CAUTION
NOTICE (NOTE)
These international safety symbols are used through-
out this manual to inform the end user, installer, and
owner of important safety information and notices for
safe and effective use of the equipment.

Important Safety Instructions

CAUTION
Under NO circumstances should anyone enter
the water with the electrical equipment plugged
in and/or in operation. It is NEVER recom-
mended to enter the water with the equipment
in operation.
Caution should be used when dealing with any
electrical equipment with moving parts.
NEVER run the unit out of water. It will dam-
age the seals and create a dangerous situation
for the operator.
Extreme caution should be used around water,
especially cold water, such as in Spring, Fall,
and Winter, which poses a hazard in and of
itself.
NEVER lift or drag the unit by the power or
light cord. If you need to pull the unit to the
side of the pond, use the anchoring ropes.
Do not use waders in deep ponds/lakes or
ponds/lakes with drop-offs, drastic slopes, or
soft bottom material.
Do not use boats that tip easily for fountain
installation, such as a canoe, and follow all
boating safety rules and regulations, including
wearing a PFD. (Personal Flotation Device)
The unit is supplied with an internal ground-
ing conductor. To reduce the risk of electrical
shock, be certain that the unit is plugged/con-
nected to an approved RCD (GFCI) protected
circuit.
Means for disconnection must be incorporated
in the fi xed wiring in accordance with local and
national wiring rules.
Consult a qualifi ed electrician for electrical
installation.
2

Unit Specs

Model
Voltage Operating
3.1EVFX
208-240
8400EJF
208-240
3.1EJF
208-240

Quick Disconnect Installation

Important – Read Carefully Before Installation
Before using the connector, it is important that these
instructions are carefully read and understood to
ensure the connector system is completely water tight
and electrically safe.
IF IN DOUBT CONSULT A QUALIFIED ELECTRI-
CIAN.
The socket (female) insert of the connector must be
the live part of the connector from the supply. The pin
(male) insert of the connector must lead to the load or
electrical device. On 50Hz units, the pin (male) insert
of the connector is installed at the factory. To ensure
effi cient sealing, use only smooth circular cable.
Pin Insert (Installed on Stub Cord)
Main Body
Pin Insert
Socket Insert (User Installed)
Socket insert
Main Body
Note:
White gland for 9-11mm O.D.
Yellow gland for 13-15mm O.D.
lock rotor
amps
amps
12.5@240V 60@240V
9.5@240V
40@240V
13.2@240V 60@240V
Gland
Gland Nut
Gland
Gland Nut