STANDARD OPERATION OPTIONS
JUMPER J1
JUMPER J2
DIP SWITCH 1
DIP SWITCH 2
DIP SWITCH 3
DIP SWITCH 4
DIP SWITCH 5
DIP SWITCH 6
DIP SWITCH 7
DIP SWITCH 8
DIP SWITCH ON
FUNCTION ACTIVE
NORMAL/APARTMENT BLOCK OPERATION - This selection enables
modifications to the operation of the PP input in apartment blocks; on
each command via radio or pushbutton opening is activated.
FLASHING UNIT/COURTESY LAMP FUNCTION - This enables the
user to select whether to enable the output for a flashing unit or that
of a courtesy lamp.
SLIDING MODE - This selection enables cancellation of delays on leaf
2 and partial opening of motor M2 with the PEDESTRIAN command.
PHOTOCELL PAUSE ON OPENING FUNCTION - This selection
enables the user to change the standard photocell operating mode.
During the opening phase, if the beam is interrupted the gate stops and
when the photocell beam is restored the gate resumes opening.
During the closing phase, if the photocell beam is interrupted the gate
stops and when the beam is restored the gate inverts movement to
open again.
AUTOMATIC CLOSING DISABLE FUNCTION - This selection enables
the user to disable the automatic closing function. On completion of
opening the gate is not set to pause for the set time, but remains
stationary on standby for a new close command.
WORKING TIME EXTENSION FUNCTION - This selection enables the
user to double the working time of the gate from the setting
of 0 to 120 sec.
OVERPUSHING STROKE FUNCTION - This selection enables the
system , on the initial opening phase, to perform a brief closure
movement of the motors to facilitate mechanical release of the
electric lock.
FLASHING UNIT WARNING TIME FUNCTION - This selection enables
activation of the flashing unit 3 seconds before each opening or closing
movement.
STEP MODE WITH PAUSE FUNCTION - This selection enables the
user to change from the standard operation of step mode (open stop
close) to an open-pause-close-pause sequence command.
NOT USED