At the recommended height of 2.1m (7ft) to 2.7m
(9ft) ± 10%, MG-PMD85 provides full coverage
from 1.5m (5ft) to 11m (35ft) as shown in Figure 5
on page 32. The MG-PMD85 includes a
weatherproof casing so it can be installed outside.
Avoid placing the detector within proximity of the
following sources of interference such as direct
sunlight, reflective surfaces and moving cars.
Do not touch the sensor surface as this
could result in a detector malfunction. If
necessary, clean the sensor surface using a
soft cloth with pure alcohol.
Avoid bending, cutting or altering the
antenna or mounting the detector near or on
metal, such as aluminum siding, as this may
affect signal transmission.
After selecting the detector's location, drill or punch
out holes for the screws (Figure 4 on page 31).
The
the Paradox Swivel Mount Bracket (469). The
swivel mount may allow for easier mounting. If
using the swivel mount, it is recommended that
you seal the space where the swivel mount is
connected to the back cover with some silicon
or with a rubber gasket to ensure that moisture
does not enter the detector.