To the Fitter
Ensure all relevant personnel read the points listed
below and that a copy is passed on to the end
user.
To the User
Read the points listed below before installation
and use of equipment.
Application
The Gulper 320 self-priming pump has been
specifically designed to pump waste water from
the shower tray/galley sink, (either overboard or
from a holding tank) or as a small bilge pump.
Output capacity depends on installation and
operating conditions.
Note:
1. If it is intended for use for any other purpose or
with any other liquid, it is the user's responsibility
to ensure that the pump is suitable for the
intended use and, in particular, that the materials
are fully compatible with the liquids to be used.
2. With all applications it is important that a system
of safe working practice is applied to Installation,
use and maintenance.
3. When used as a bilge pump users should be
aware that capacity may not be sufficient to cope
with rapid influx of water.
4. Suitable for a bilge pump for boats smaller than
12 metres/39.4 ft (designed to ISO15083).
Installation
Choose a position to mount the pump that is dry
and away from casual water. The pump may be
mounted on a horizontal or vertical surface. When
mounted vertically ensure that the pump head is
lower most (see diagram below).
When mounting, position the pump on the
intended surface and work-out the best angles for
the hose, then mark the 3 hole positions using the
pump feet. The pump head may be rotated to suit
the hose connections, this is done by loosening
High Capacity Shower/Galley Waste and Bilge Pump
X
3
the screw that holds the clamping rings, and
rotating the pump head. Once you have marked
the position for the three mounting feet, drill pilot
1 /
holes of 3.2mm (
). Use the three No.8 self
8 "
tappers and washers to secure the pump. Use
3 /
19mm (
) or 25mm (1") smooth bore reinforced
4 "
hose to connect to the pump.
Electrical Connections
The polarity is indicated by coloured cable
(Positive - red, Negative - black). The pump is
protected against reverse polarity connection.
Minimum wire size is 1.5mm 2 (16 AWG). (Note:
undersized wire reduces voltage under load at the
pump, thus giving poor performance and potential
motor failure). The in-line fuse assembly supplied
(see details below) must be fitted to the positive
side of the pump.
Purpose
The purpose of this fuse is to protect the pump
from serious damage in the event of system
blockages, therefore please ensure all valves are
fully open before operating the pump.
Connection Instructions
Insert this fuse assembly between the positive
terminal on the pump and the positive feed wire.
Note:
1. If the fuse blows check:
a) all system valves/stop cocks are open.
b) the inlet and outlet nipples are not blocked
c) the remainder of the system is not blocked in
any way.
2. Fuse rating for BP2052 (12v DC) pumps 10 amp
automotive. Fuse rating for BP2054 (24v DC)
pumps 5 amp automotive
To control the pump an in-line switch should be
fitted between the positive live terminal on the
battery and the positive lead on the pump. If using
an automatic switch (such as a float switch) an
isolator switch should be fitted.
Operation
The Gulper 320 is switched on by either a remote
on/off switch or an automatic float switch. When
used to drain a shower or galley, the flow rate
should be sufficient to take away the waste faster
than the delivery from either the shower or galley
tap.
Gulper 320