IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
*
**
Electric warm air hand dryer intended for use in a household environment
by non-expert users. Not suitable for outdoor use.
***
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
**** If a fault develops disconnect the electrical supply, a qualified
electrician should be called.
SAVE THESE INSTRUCTIONS
*****
Model B-7120 White Painted Steel Cover and B-7128 Stainless Steel Cover, 115V AC, 15 Amp, 1725 Watts, 50/60 Hz, Single Phase, cULus listed.
Model B-7120 White Painted Steel Cover and B-7128 Stainless Steel Cover, 208–240V AC, 6.8-7.8 Amp, 1400-1900 Watts, 50/60 Hz, Single
Phase; cULus listed, VDE and CE marked.
Installation instructions and template provide information that will assist in the installation of the Bobrick B-7120 and B-7128 115V, B-7120 and B-7128
208-240V. Retain Installation Instruction Sheet for important maintenance instructions and warranty information.
Distance from floor to bottom mounting screw holes of mounting base.
Children's Washrooms, ages 3-4 .............................................................................................................................................................. 36'' (915mm)
Children's Washrooms, ages 5-8 .............................................................................................................................................................. 40'' (1015mm)
Children's Washrooms, ages 9-12 ............................................................................................................................................................ 44'' (1120mm)
Universal Design ...................................................................................................................................................................................... 48'' (1219mm)
*
Bobrick automatic hand dryers should be installed at least 15" (380mm) above any projection or horizontal surface which may interfere with the
operation of the automatic sensor.
1. Start installation of dryer by
removing cover. Remove two
screws, from the bottom of the
dryer.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL
BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED
LICENSED ELECTRICIAN
1. Hold the Installation Template against the wall in the desired location of
the installed dryer. See recommended mounting heights above.
2. Make sure line on template representing bottom of dryer mounting base
is horizontal and located at the desired height above floor.
3. Mark center of four mounting screw holes and hole for entry of electrical
wiring if electrical supply is concealed in wall and will enter dryer from
back through mounting base.
NOTE: Surface-mounted electrical supply entry is located in the lower right
corner of the mounting base. Surface-mounted supply cable should be fitted
in a conduit.
4. For brick, stone, and concrete walls drill four 0.315" (8mm) holes to suit
wall plugs 0.315" (8mm) x 1-1/4" (45mm) and screws#10 (4.8mm) x 2"
(50mm) long (provided). See template for wall plug and screw
installation details.
5. For plaster or dry wall construction, provide concealed backing to
comply with local building codes and secure with four #10 (M4.8) round-
head sheet-metal screws, or 3/16'' (5mm) toggle bolts (not furnished).
6. Fasten mounting base securely to wall.
2
Electrical Characteristics
Recommended Mounting Heights
Removal of Cover
Installation of Mounting Base
Form No. 712-69 Multi Language (Rev. 2/19/18)
2. Rotate bottom of cover away
from mounting base and then lift
up.
Ø 5/16" 8mm
1.
x 4
WARNING: TURN ELECTRICAL POWER SUPPLY OFF BEFORE
MAKING ELECTRICAL CONNECTIONS.
DRYER MUST BE GROUNDED (EARTHED).
© 2018 Bobrick Washroom Equipment, Inc.
13-25/32" 350mm
9-1/4" 235mm
Ø7/8" 22mm
Hole for between wall wiring
2.
3.
Ø7/8" 22mm
Hole for between wall wiring
Flange cutout for
surface mounting