Electrode setting

Check the position of the factory set electrodes complying with
the Fig. 22.
Before removing or assembling the nozzle, loosen the screw
1)(Fig. 22) and move the electrodes ahead.
Model
TIGRA 2 CF 510-510 R
TIGRA 2 CF 710-710 R
3.8

Fuel heating

TIGRA 2 CF 510
In order to obtain smooth starting and operation across its output
range the burner is fitted with an electric resistance, which heats
up the light oil in the nozzle line.
This heater (R) is energized when the limit thermostat (TL) calls
for heat, and at the same time the motor will start.
The heater remains energised during working and cuts out when
burner shuts-down.
20018247
Burner operation
D9859
A
B
7
2.5
1.5 - 2
4.6
3
1 - 1.5
Measures must be respected.
WARNING
C
D
see Tab. A
see Tab. A
TIGRA 2 CF 510 R - TIGRA 2 CF 710 R
In order to obtain smooth starting and operation across its output
range the burner is fitted with an electric resistance, which heats
up the light oil in the nozzle line.
This heater (R) is energized when the limit thermostat (TL) calls
for heat and after a delay of approximately two minutes depen-
ding on room temperature, the motor will start.
The heater (R) remains energised during working and cuts out
when burner shuts-down.