Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The drain valve must only be used as intended. It is
not allowed to attach other objects to the drain
valve, for example a semi-pedestal.
• If necessary shorten platic hose according to the
table and insert it up to the collar into the shorter
blue marked copper pipe.
Technical Data
Operating pressure:
Recommended operating pressure:
Highest possible water pressure at
user's site in Mpa
0,1 - 0,15
0,2 - 0,3
0,4 - 0,7
If the water pressure is greater than 0,5 MPa, fit a pressure reducing valve.
Fault
Insufficient water
Mixer stiff
Mixer dripping constantly with water
heater switched off
4
English
max. 1 MPa
0,1 - 0,5 MPa
Table for the throttle hose lengths to be used
8, 10 and 15 liters
without throttle hose
Throttle hose shortened to 90 mm
Cause
- Spray former calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
Assembly (see page 33)
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Rate of flow:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 32)
Spare parts (see page 35)
When changing the spray former, it is imperative to use
one made for this type of mixer.
Cleaning (see page 36)
Operation (see page 34)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• When the storage tank is being heated, the spout
will drip.
Test certificate (see page 32)
Device content
Throttle hose shortened to 90 mm
Throttle hose unchanged
Adjust flow volume at corner valve
Remedy
- Clean spray former, exchanging if
necessary
- Exchange cartridge
- Exchange cartridge
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 5 l/min
max. 70°C ⁄ 4 min
up to 5 liters
Throttle hose unchanged
65°C