CORE PROBE SPIKE

Select by pressing button 17 and with the core probe display lit.
SELECTED TEMP.
TRUE OVEN TEMP.
OVEN TEMP. SELECTION
SELECTED CORE TEMP.
TRUE CORE TEMP.
CORE PROBE TEMP.
SELECTION
CORE PROBE FUNCTION
DISPLAY
5.6.2

DELTA FUNCTION

It is the difference between the core temperature and the oven temperature.
The oven temperature is always 50 ºC higher than the temperature recorded by the core probe.
Select by pressing button 17 and with the delta display lit.
PROBE TEMP. +50 ºC
TRUE OVEN TEMP.
FUNCTION CANCELLED
SELECTED CORE TEMP.
TRUE CORE TEMP.
CORE PROBE TEMP.
SELECTION
DELTA FUNCTION DISPLAY
5.6.3

COOL DOWN

To cool the cooking chamber, proceed as follows:
Close the door and press button 21 (COOL DOWN). Next open the
door.
The fan starts and the cool down LED indicator light, number 21, lights
up. When the chamber temperature reaches 45 ºC, the fan stops
automatically.
The cooling cycle can be stopped by pressing button 20 again or by
closing the door, and the cool down indicator will go out.
Warning: Do not cool the oven by directly applying cold water in the tub.
SAFETY MEASURES: The fan cover and the tray guides must be
correctly fastened in place during this cycle.
The cooking chamber must not be cooled with cold water.
Turn control 13 to select the required core
temperature.
Window 12 displays the selected core
temperature from 0 to 99°C.
Window 11 displays the true temperature in the
core probe.
Turn control 10 to select the oven chamber
temperature.
Window 8 displays the selected oven
temperature.
Window 8 displays the true temperature in the
oven chamber.
When the core temperature reaches the
required temperature, the oven stops and an
alarm is heard.
Turn control 13 to select the required core
temperature (for example 70 ºC) displayed in
window 12.
Insert spike probe in food (for example 15 °C)
displayed in window 11.
The oven will heat up to 15 ºC+50 ºC  65 °C
and as the temperature of the core rises, the
oven temperature will increase, always
maintaining a difference of +50 ºC.
When the core temperature reaches the selected
70 ºC, the oven temperature is 120 ºC and an
alarm will be heard.
In this function, control 10 (for selecting the oven
temperature) is inoperative.
In steam mode, set at 99°C, the adjustment
range is only from 0 to 49°C.
In the convection and mixed modes, the
adjustment range is from 0 to 99°C.
21 Cool down
Led cool down
57