Technical Information
Selection buttons
After connection, the selection buttons will flash.
Press the button of the appropriate limit switching version of the tubular drive:
Tubular drive with mechanical limit switching
Tubular drive with electronic limit switching
Tubular drive with electronic limit switching and radio
Control buttons
Travel buttons
For tubular drives with mechanical limit switching, the travel buttons are switched to main-
tained operation. For tubular drives with electronic limit switching with and without radio,
the travel buttons are switched to dead-man mode.
Stop button
Reversal of the travel buttons
In order to adapt the function of the UP and DOWN travel buttons to the actual direction of
travel of the drive, these can be swapped.
Note
As soon as the programming unit is disconnected from the power supply,
the function of the travel buttons returns to the factory default.
Press the stop button for 5 seconds. The control buttons UP, STOP, DOWN flash 3 times to
confirm.
6
de
en
fr
es
it
cs
Becker-Antriebe GmbH
Friedrich-Ebert-Str. 2-4
35764 Sinn/Germany
www.becker-antriebe.com
nl
tr