Connecting The Dirt Outlet; Connecting The Pond Aerator; Commissioning/Start-Up - Oase ProfiClear Premium XL Moving Bed Modul Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
4.2

Connecting the dirt outlet

 A
The water in the container can be drained via the DN 75 dirt outlet with slide valve at the bottom of the
container if required (for cleaning, repair, overwintering).
• Connect a suitable DN 75 pipe and drain the dirty water into the sewer system.
T I P
It is possible to bring together pipe DN 75 and pipe DN 110 from the drum filter for coarse dirt
in order to drain the dirty water into the sewer system through a joint pipe DN 110.
This makes it more convenient to flush out the dirty water pipe with sufficient pressure.
4.3

Connecting the pond aerator

The aerator stones in the container are supplied with air by a pond aerator.
• Pond aerator recommendation: OASE AquaOxy 4800.
• To ensure effective water circulation, AquaOxy 4800 may only supply air to one ProfiClear Premium
XL Moving Bed module.
How to proceed:
 D
1. Connect the hose from the pond aerator with the air connection and insert the air connection into
the recess of the container.
– Secure the air hose with a hose clip.
5

Commissioning/start-up

The ProfiClear Premium XL Moving Bed module can be filled either only with Pond Pads or with a mix
of Pond Pads and Hel-X.
Filling of ProfiClear Premium XL Moving Bed module
Pond Pads only
Min. amount
60 litres
Available package sizes:
• Pond Pads: Bag, 20 litres each
• Hel-X: Bag, 25 litres each
T I P
• It can take up to 8 weeks for the Pond Pads/Hel-X to be fully colonised with bacteria.
• If more than 60 l of Pond Pads are used, add the additional volume gradually. We recom-
mend adding max. 5 l per week.
Mix of Pond Pads and Hel-X
Max. amount
Max. amount Hel-X
100 litres
100 litres
- EN -
In addition max. amount Pond Pads
50 litres
21

Publicidad

Tabla de contenido
loading

Tabla de contenido