Installation And Connection; Installing The Filter Module And Connecting It With The Upstream Filter Module; Connecting The Dirt Outlet; Connecting The Pond Aerator - Oase ProfiClear Premium XL Discharge Module Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
4

Installation and connection

4.1

Installing the filter module and connecting it with the upstream filter module

How to proceed:
 D
1. Push the transition sleeve onto the inlet and fasten it with the hose clip.
– For later assembly work, turn the hose clip so that the hose clip screw is accessible from the
side.
2. Push the filter module up to the previous filter module so that its outlet is positioned in the transition
sleeve of the filter module up to the stop.
– Ensure that the soiled water outlets are all on the same side.
3. Secure the connection with a hose clip.
– For later assembly work, turn the hose clip so that the hose clip screw is accessible from the
side.
4.2

Connecting the dirt outlet

 A, B
The water in the container can be drained via the DN 75 dirt outlet with slide valve at the bottom of the
container if required (for cleaning, repair, overwintering).
• Connect a suitable DN 75 pipe and drain the dirty water into the sewer system.
T I P
It is possible to bring together pipe DN 75 and pipe DN 110 from the drum filter for coarse dirt
in order to drain the dirty water into the sewer system through a joint pipe DN 110.
This makes it more convenient to flush out the dirty water pipe with sufficient pressure.
4.3

Connecting the pond aerator

(Only pump-fed ProfiClear Premium XL drain module)
Use of aerator stones promotes water circulation in the container and is ideal for ensuring even bacte-
rial colonisation of the ClearWaves.
• Recommended pond aerator: AquaOxy 1000 or 2000.
How to proceed:
 E
1. Connect the hose from the pond aerator with the air connection and insert the air connection into
the recess of the container.
– For a ∅ 4 mm air hose, use the 4/9-mm adapter.
– For connecting the AquaOxy 1000/2000, use the Y distributor.
– If necessary, secure the connections with cable ties.