- EN -
Remedy of faults
Malfunction
None of the lamps are lit.
One of the spotlights is not lit.
Luminous intensity of a spotlight is insufficient.
Cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
If necessary, clean the unit with clear water using a soft brush.
• Ensure that no moisture can enter the unit.
Storage/overwintering
The unit must be removed and stored in a dry place if temperatures outside the permissible ambient temperatures are
expected.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for
this purpose.
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
14
Cause
No supply voltage
Controller defective
Spotlight not connected
Spotlight defective
The controller output is defective.
Protection lens soiled
www.oase-livingwater.com/spareparts
Remedy
Check all cables and connections.
Replace the controller.
Check the connection between spotlight and
controller.
Replace the spotlight.
Replace the controller.
Clean the protection lens.