Low level configuration (AC-MAX ST (V2.0), LT (V2.0))
Table 6. List of low level parameters
Communication settings
RS485 address
RS485 communication timeout [s]
RS485 encryption
RS485 encryption key
Input types
IN1 – IN8
Input response times
IN1 – IN8 [ms]
Output polarity
REL1 – REL8
Comments
DEV
Input comments
IN1 - IN8
Output comments
REL1 – REL8
High level configuration (AC-MAX)
The purpose of high level configuration is to define logical functioning of the expander which communicates
with the AC-MAX CU access controller and it depends on applied scenario of operation.
Parameter defines device address on RS485 bus. Range: 100-115.
Default value: 110.
Parameter defines delay after which device will signal lost
communication with controller. When set to 0 then signaling is
disabled. Range: 0-64s. Default value: 20s.
Parameter enables encryption at RS485 bus. Range: [0]: No, [1]: Yes.
Default value: [0]: No.
Parameter defines key for encryption of communication at RS485 bus.
Range: 4-16 ASCII characters.
Parameter defines input type. Range: [1]: NO, [2]: NC. Default value:
[1]: NO.
Parameter defines minimal duration of pulse which is required to
trigger the input. Range: 50-5000. Default value: 50.
Parameter defines polarity of output. Normal polarity means that the
output by default is switched off while Reversed polarity means that
the output by default is switched on. Range: [0]: Normal polarity, [1]:
Reversed polarity. Default value: [0]: Normal polarity.
Parameter defines any text or comment which corresponds to the
device. It is later displayed in AC-MAX program.
Parameter defines any text or comment which corresponds to the
object. It is later displayed in AC-MAX program.
Parameter defines any text or comment which corresponds to the
object. It is later displayed in AC-MAX program.