PECIFICATION
Table 7. Specification
Supply voltage
Current consumption (average)
Inputs
Relay outputs
Distances
IP Code
Environmental class (according to
EN 50133-1)
Dimensions W x S x G
Weight
Certificates
7. I
NFORMATION
Table 8. Information
EXP8-IO
Nominal 12VDC, min./max. range 10-15VDC
30mA (when relays off)
EXP8-IO: Eight (IN1..IN8)
parametric inputs internally connected to the power supply plus
(+12V) through a 15kΩ resistor, approx. 3.5V triggering level when
configured as NO or NC.
EXP8-IO: Eight relay outputs:
REL1..REL8: 30VDC/1.5A
Each with single NO/NC contacts.
Up to 1200 m between controller and expander (RS485)
IP20
Class I, indoor general conditions, temperature: +5°C to +40°C,
relative humidity: 10 to 95% (no condensation)
EXP8:
EXP8:
CE
I/O expander; 8 supervised inputs; 8 relay outputs 1.5 A/30 V; 13.8 VDC supply
input
This symbol placed on a product or packaging indicates that the product
should not be disposed of with other wastes as this may have a negative
impact on the environment and health. The user is obliged to deliver
equipment to the designated collection points of electric and electronic
waste. For detailed information on recycling, contact your local authorities,
waste disposal company or point of purchase. Separate collection and
recycling of this type of waste contributes to the protection of the natural
resources and is safe to health and the environment. Weight of the
equipment is specified in the document.
72 x 155 x 20 mm
115g